DOI 10.1016/j.hlc.2017.04.006

Медицинская библиотека · Heart, lung & circulation · 2017

The Applicability of the American College of Cardiology Appropriate Use Criteria for Myocardial Perfusion Scintigraphy in Australia.

Chow Chee Loong, Ponnuthurai Francis A, Allman Kevin C, van Gaal William

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The American College of Cardiology (ACC) Appropriate Use Criteria (AUC) for radionuclide myocardial perfusion scans (MPS) was developed to promote its rational use in the assessment of stable ischaemic heart disease (IHD). We sought to validate the applicability of this document in the Australian context.

METHODS

1009 consecutive patients who underwent MPS were retrospectively audited at a single major metropolitan hospital in Victoria, Australia. Appropriateness was assigned based on the 2013 ACC AUC, and common indications and predictors of positive scan results were examined.

RESULTS

The AUC was successfully applied (99.1%) retrospectively. A large proportion of scans were deemed appropriate (82.7%), whilst 7.8% were maybe appropriate. Positive detection rates in these groups were 17.0% and 17.9% respectively. Eighteen patients (1.8%) were unclassifiable, but had a detection rate of 44.4%. Positive predictors of an abnormal MPS result included prior history of coronary artery disease, typical angina, and following the conservative management of an acute coronary syndrome. Scans that were rarely appropriate had a detection rate of 0%.

CONCLUSION

The retrospective application of the 2013 ACC AUC is feasible. Whilst the majority of the scans were appropriate, a group of unclassifiable patients was observed to have a high detection rate. Scans that were rarely appropriate could potentially be rationalised to reduce radiation risk.

Для цитирования: Chow Chee Loong, Ponnuthurai Francis A, Allman Kevin C, van Gaal William. The Applicability of the American College of Cardiology Appropriate Use Criteria for Myocardial Perfusion Scintigraphy in Australia.. Heart, lung & circulation. 2017. DOI: 10.1016/j.hlc.2017.04.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.