MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/anie.202501231

Медицинская библиотека · Angewandte Chemie (International ed. in English) · 2025

Scalable Hyperpolarized MRI Enabled by Ace-SABRE of [1-13C]Pyruvate.

McBride Stephen J, Pike Megan, Curran Erica, Zavriyev Alexander, Adebesin Bukola, Tucker Luke, Harzan Jared M, Senanayake Ishani M, Abdulmojeed Mustapha, Theiss Franziska, Shen Sheng, Boele Thomas, Duckett Simon B, Goodson Boyd M, Rosen Matthew S, Chekmenev Eduard Y, Yuan Hong, Dedesma Carlos, Gade Terence, Kadlecek Stephen, Theis Thomas, TomHon Patrick

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Hyperpolarized (HP) MRI using [1-13C]pyruvate is emerging as a promising molecular imaging approach. Among hyperpolarization methods, Signal Amplification By Reversible Exchange (SABRE) is attractive because SABRE polarizes the substrates directly in room-temperature solutions avoiding complex hardware. Most SABRE experiments have historically been performed in methanol, a relatively toxic and difficult-to-remove solvent. Here we demonstrate the use of a 80/20 acetone/water (A/W) solvent system (Ace-SABRE) to provide hyperpolarized [1-13C]pyruvate with up to 17% polarization, then implement a solvent processing protocol to achieve injectable solutions retaining 74% of the initial polarization, and lastly we demonstrate HP in vivo spectroscopy and imaging using the Ace-SABRE platform to showcase metabolic tracking in a hepatocellular carcinoma (HCC) tumor as well as HP-MRI, both in direct comparison to dissolution dynamic nuclear polarization (d-DNP) experiments. The Ace-SABRE technique promises faster adoption of SABRE hyperpolarization in biological experiments, overall lowering the barriers to entry for HP-NMR and HP-MRI.

Для цитирования: McBride Stephen J, Pike Megan, Curran Erica, Zavriyev Alexander, Adebesin Bukola, Tucker Luke, Harzan Jared M, Senanayake Ishani M, Abdulmojeed Mustapha, Theiss Franziska, Shen Sheng, Boele Thomas, Duckett Simon B, Goodson Boyd M, Rosen Matthew S, Chekmenev Eduard Y, Yuan Hong, Dedesma Carlos, Gade Terence, Kadlecek Stephen, Theis Thomas, TomHon Patrick. Scalable Hyperpolarized MRI Enabled by Ace-SABRE of [1-13C]Pyruvate.. Angewandte Chemie (International ed. in English). 2025. DOI: 10.1002/anie.202501231.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.