INTRODUCTION

Aortic valve replacement (AVR) via right anterior mini-thoracotomy (RAMT) is less traumatic than via other surgical routes; using a novel aortic valve may confer long-term resistance against valve deterioration, and thus be useful in younger, more active patients. Here we aim to validate using the INSPIRIS RESILIA valve with minimally invasive RAMT.

METHODS

Between April 2017 and June 2019, 100 patients underwent video-assisted minimally invasive AVR by RAMT, using the INSPIRIS RESILIA aortic valve. Cannulation for cardiopulmonary bypass (CPB) was through femoral vessels. Clinical data were prospectively entered into our institutional database.

RESULTS

Cardiopulmonary bypass (CPB) and cross-clamping times were 79 ± 38 and 41 ± 17 min. Surgical access was successful in 100% of cases. There were no cases of intraoperative mortality, 30-day mortality, cerebrovascular events, rethoracotomy for bleeding, valve-related reoperation, right internal mammary artery injury, or conversion to sternotomy. Intensive care and hospital stays were 2 ± 1 and 6 ± 3 days, respectively. One patient had a pacemaker fitted. Postoperative dialysis was necessary in one patient. Trace to mild aortic valve regurgitation occurred in two patients. No structural valve deterioration (SVD) and paravalvular leak were seen. At 1-year follow-up mean effective orifice area (EOA) was 1.8 ± 0.1 cm2, peak gradient was 22.1 ± 3.1 mmHg, and mean gradient was 11.5 ± 2.3 mmHg.

CONCLUSION

Our preliminary experience suggests that RAMT for AVR using the INSPIRIS RESILIA aortic valve is safe, effective, and reproducible. Larger studies are needed to evaluate the long-term efficacy and durability of this new valve.

Для цитирования: El-Sayed Ahmad Ali, Salamate Saad, Amer Mohamed, Sirat Sami, Akhavuz Ömur, Bakhtiary Farhad. The First 100 Cases of Two Innovations Combined: Video-Assisted Minimally Invasive Aortic Valve Replacement Through Right Anterior Mini-Thoracotomy Using a Novel Aortic Prosthesis.. Advances in therapy. 2021. DOI: 10.1007/s12325-021-01705-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.