MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12889-019-8069-2

Медицинская библиотека · BMC public health · 2019

MOBIlity assessment with modern TEChnology in older patients' real-life by the General Practitioner: the MOBITEC-GP study protocol.

Münch Mareike, Weibel Robert, Sofios Alexandros, Huang Haosheng, Infanger Denis, Portegijs Erja, Giannouli Eleftheria, Mundwiler Jonas, Conrow Lindsey, Rantanen Taina, Schmidt-Trucksäss Arno, Zeller Andreas, Hinrichs Timo

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Mobility limitations in older adults are associated with poor clinical outcomes including higher mortality and disability rates. A decline in mobility (including physical function and life-space) is detectable and should be discovered as early as possible, as it can still be stabilized or even reversed in early stages by targeted interventions. General practitioners (GPs) would be in the ideal position to monitor the mobility of their older patients. However, easy-to-use and valid instruments for GPs to conduct mobility assessment in the real-life practice setting are missing. Modern technologies such as the global positioning system (GPS) and inertial measurement units (IMUs) - nowadays embedded in every smartphone - could facilitate monitoring of different aspects of mobility in the GP's practice.

METHODS

This project's aim is to provide GPs with a novel smartphone application that allows them to quantify their older patients' mobility. The project consists of three parts: development of the GPS- and IMU-based application, evaluation of its validity and reliability (Study 1), and evaluation of its applicability and acceptance (Study 2). In Study 1, participants (target N = 72, aged 65+, ≥2 chronic diseases) will perform a battery of walking tests (varying distances; varying levels of standardization). Besides videotaping and timing (gold standard), a high-end GPS device, a medium-accuracy GPS/IMU logger and three different smartphone models will be used to determine mobility parameters such as gait speed. Furthermore, participants will wear the medium-accuracy GPS/IMU logger and a smartphone for a week to determine their life-space mobility. Participants will be re-assessed after 1 week. In Study 2, participants (target N = 60, aged 65+, ≥2 chronic diseases) will be instructed on how to use the application by themselves. Participants will perform mobility assessments independently at their own homes. Aggregated test results will also be presented to GPs. Acceptance of the application will be assessed among patients and GPs. The application will then be finalized and publicly released.

DISCUSSION: If successful, the MOBITEC-GP application will offer health care providers the opportunity to follow their patients' mobility over time and to recognize impending needs (e.g. for targeted exercise) within pre-clinical stages of decline.

Для цитирования: Münch Mareike, Weibel Robert, Sofios Alexandros, Huang Haosheng, Infanger Denis, Portegijs Erja, Giannouli Eleftheria, Mundwiler Jonas, Conrow Lindsey, Rantanen Taina, Schmidt-Trucksäss Arno, Zeller Andreas, Hinrichs Timo. MOBIlity assessment with modern TEChnology in older patients' real-life by the General Practitioner: the MOBITEC-GP study protocol.. BMC public health. 2019. DOI: 10.1186/s12889-019-8069-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.