MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s26144336

Медицинская библиотека · Sensors (Basel, Switzerland) · 2026

Packaging Design and Thermal Characterization of 3D Double-Sided Cooling Automotive SiC Power Modules with Reliable Junction Temperature Sensing.

Li Chunzhen, Lin Tianliang, Guo Xinhua, Wang Rongkun, Chen Yuanxi, Zhou Siqi

СтатьяПеревод в очереди

Аннотация

Accurate junction temperature (Tj) sensing is essential for the reliability of silicon carbide (SiC) power modules in electric vehicles. Nonetheless, the physical separation and consequent thermal signal delay between sensing elements and chips pose significant challenges to precise junction temperature monitoring. To solve this issue, an embedded temperature sensing structure integrated into the designed double-sided cooling (DSC) SiC power module is proposed, which leverages 3D vertical interconnects to enhance temperature observability. The customized design of a copper spacer serves as the primary heat dissipation path and electrical connection between the upper and lower chips in the same location. A compact thermal resistance network and 3D finite-element simulations are developed to reveal the vertical thermal coupling between the spacers and the chips, enabling accurate junction temperature estimation from spacer temperature. The proposed concept is experimentally validated on a fabricated prototype using embedded K-type thermocouples and an IR camera under power cycling conditions. The measured temperature differences between the copper spacers and the junction temperature are maintained within approximately 0.5-2 °C under the tested operating range. This approach provides a potential application in real-time condition monitoring and thermal management in high-power-density electric drives.

Для цитирования: Li Chunzhen, Lin Tianliang, Guo Xinhua, Wang Rongkun, Chen Yuanxi, Zhou Siqi. Packaging Design and Thermal Characterization of 3D Double-Sided Cooling Automotive SiC Power Modules with Reliable Junction Temperature Sensing.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26144336.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.