MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/ice.2020.11

Медицинская библиотека · Infection control and hospital epidemiology · 2020

Bioaerosols generated from toilet flushing in rooms of patients with Clostridioides difficile infection.

Wilson Geneva M, Jackson Virgil B, Boyken Linda D, Schweizer Marin L, Diekema Daniel J, Petersen Christine A, Breheny Patrick J, Nonnenmann Matthew W, Perencevich Eli N, CDC Prevention Epicenter Program

Сравнительное исследованиеСтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

BACKGROUND

Clostridioides difficile infection (CDI) is the most frequently reported hospital-acquired infection in the United States. Bioaerosols generated during toilet flushing are a possible mechanism for the spread of this pathogen in clinical settings.

OBJECTIVE

To measure the bioaerosol concentration from toilets of patients with CDI before and after flushing.

DESIGN

In this pilot study, bioaerosols were collected 0.15 m, 0.5 m, and 1.0 m from the rims of the toilets in the bathrooms of hospitalized patients with CDI. Inhibitory, selective media were used to detect C. difficile and other facultative anaerobes. Room air was collected continuously for 20 minutes with a bioaerosol sampler before and after toilet flushing. Wilcoxon rank-sum tests were used to assess the difference in bioaerosol production before and after flushing.

SETTING

Rooms of patients with CDI at University of Iowa Hospitals and Clinics.

RESULTS

Bacteria were positively cultured from 8 of 24 rooms (33%). In total, 72 preflush and 72 postflush samples were collected; 9 of the preflush samples (13%) and 19 of the postflush samples (26%) were culture positive for healthcare-associated bacteria. The predominant species cultured were Enterococcus faecalis, E. faecium, and C. difficile. Compared to the preflush samples, the postflush samples showed significant increases in the concentrations of the 2 large particle-size categories: 5.0 µm (P = .0095) and 10.0 µm (P = .0082).

CONCLUSIONS

Bioaerosols produced by toilet flushing potentially contribute to hospital environmental contamination. Prevention measures (eg, toilet lids) should be evaluated as interventions to prevent toilet-associated environmental contamination in clinical settings.

Для цитирования: Wilson Geneva M, Jackson Virgil B, Boyken Linda D, Schweizer Marin L, Diekema Daniel J, Petersen Christine A, Breheny Patrick J, Nonnenmann Matthew W, Perencevich Eli N, CDC Prevention Epicenter Program. Bioaerosols generated from toilet flushing in rooms of patients with Clostridioides difficile infection.. Infection control and hospital epidemiology. 2020. DOI: 10.1017/ice.2020.11.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.