Медицинская библиотека · Gastrointestinal endoscopy · 2015

Systematic review on bedside electromagnetic-guided, endoscopic, and fluoroscopic placement of nasoenteral feeding tubes.

Gerritsen Arja, van der Poel Marcel J, de Rooij Thijs, Molenaar I Quintus, Bergman Jacques J, Busch Olivier R, Mathus-Vliegen Elisabeth M, Besselink Marc G

Сравнительное исследованиеСтатьяСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

Nasoenteral tube feeding is frequently required in hospitalized patients to either prevent or treat malnutrition, but data on the optimal strategy of tube placement are lacking.

OBJECTIVE

To compare the efficacy and safety of bedside electromagnetic (EM)-guided, endoscopic, and fluoroscopic placement of nasoenteral feeding tubes in adults.

DESIGN

Systematic review of the literature.

PATIENTS: Adult hospitalized patients requiring nasoenteral feeding.

INTERVENTIONS: EM-guided, endoscopic, and/or fluoroscopic nasoenteral feeding tube placement.

MAIN OUTCOME MEASUREMENTS: Success rate of tube placement and procedure- or tube-related adverse events.

RESULTS

Of 354 screened articles, 28 studies were included. Data on 4056 patients undergoing EM-guided (n = 2921), endoscopic (n = 730), and/or fluoroscopic (n = 405) nasoenteral feeding tube placement were extracted. Tube placement was successful in 3202 of 3789 (85%) EM-guided procedures compared with 706 of 793 (89%) endoscopic and 413 of 446 (93%) fluoroscopic procedures. Reinsertion rates were similar for EM-guidance (270 of 1279 [21%] patients) and endoscopy (64 of 394 [16%] patients) or fluoroscopy (10 of 38 [26%] patients). The mean (standard deviation) procedure time was shortest with EM-guided placement (13.4 [12.9] minutes), followed by endoscopy and fluoroscopy (14.9 [8.7] and 16.2 [23.6] minutes, respectively). Procedure-related adverse events were infrequent (0.4%, 4%, and 3%, respectively) and included mainly epistaxis. The tube-related adverse event rate was lowest in the EM-guided group (36 of 242 [15%] patients), followed by fluoroscopy (40 of 191 [21%] patients) and endoscopy (115 of 384 [30%] patients) and included mainly dislodgment and blockage of the tube.

LIMITATIONS: Heterogeneity and limited methodological quality of the included studies.

CONCLUSION

Bedside EM-guided placement of nasoenteral feeding tubes appears to be as safe and effective as fluoroscopic or endoscopic placement. EM-guided tube placement by nurses may be preferred over more costly procedures performed by endoscopists or radiologists, but randomized studies are lacking.

Для цитирования: Gerritsen Arja, van der Poel Marcel J, de Rooij Thijs, Molenaar I Quintus, Bergman Jacques J, Busch Olivier R, Mathus-Vliegen Elisabeth M, Besselink Marc G. Systematic review on bedside electromagnetic-guided, endoscopic, and fluoroscopic placement of nasoenteral feeding tubes.. Gastrointestinal endoscopy. 2015. DOI: 10.1016/j.gie.2014.10.040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.