MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00234-014-1320-8

Медицинская библиотека · Neuroradiology · 2014

Evaluation of a newly designed flow diverter for the treatment of intracranial aneurysms in an elastase-induced aneurysm model, in New Zealand white rabbits.

Simgen Andreas, Ley Desiree, Roth Christian, Yilmaz Umut, Körner Heiko, Mühl-Benninghaus Ruben, Kim Yoo-Jin, Scheller Bruno, Reith Wolfgang

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

In this study, we analyzed angiographic and histologic aneurysm occlusion of a newly designed flow diverting device. Visibility and flexibility, as well as occlusions of side branches and neointimal proliferation were also evaluated.

METHODS

Aneurysms were induced in 18 New Zealand white rabbits and treated with a braided, “closed-loop-designed” device of nitinol. Additional devices were implanted in the abdominal aorta to cover the origin of branch arteries.Angiographic follow-ups were performed immediately after placement of the device, after 3 months (n=9) and 6 months(n =9). The status of aneurysm occlusion (using a five-point scale) and the patency of branch arteries were assessed.

RESULTS

Aneurysm occlusion rates were noted as grade 0 in 2 (11 %), grade I in 1 (6 %), grade II in 1 (6 %), grade III in 9(50 %), and grade IV in 5 (28 %) of 18 aneurysms, respectively, indicating a complete or near-complete occlusion of 78 % under double antiplatelet therapy. Aneurysm occlusion was significantly higher at 6 months follow-up (P =0.025). Radiopaque markers provided excellent visibility. Limited device flexibility led to incomplete aneurysm neck coverage and grade 0 occlusion rates in two cases. Distal device occlusions were found in three cases, most likely due to an extremely undersized vessel diameter in the subclavian artery.No case of branch artery occlusion was seen. Intimal proliferation and diameter stenosis were moderate.

CONCLUSION

The tested flow diverter achieved near-complete and complete aneurysm occlusion under double antiplatelet therapy of elastase-induced aneurysms in 78 %, while preserving branch arteries.

Для цитирования: Simgen Andreas, Ley Desiree, Roth Christian, Yilmaz Umut, Körner Heiko, Mühl-Benninghaus Ruben, Kim Yoo-Jin, Scheller Bruno, Reith Wolfgang. Evaluation of a newly designed flow diverter for the treatment of intracranial aneurysms in an elastase-induced aneurysm model, in New Zealand white rabbits.. Neuroradiology. 2014. DOI: 10.1007/s00234-014-1320-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.