MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpba.2017.01.002

Медицинская библиотека · Journal of pharmaceutical and biomedical analysis · 2017

A highly sensitive quantum dots-DNA nanobiosensor based on fluorescence resonance energy transfer for rapid detection of nanomolar amounts of human papillomavirus 18.

Shamsipur Mojtaba, Nasirian Vahid, Mansouri Kamran, Barati Ali, Veisi-Raygani Asad, Kashanian Soheila

СтатьяПеревод в очереди

Аннотация

A very sensitive and convenient nanobiosensor based on fluorescence resonance energy transfer (FRET) was developed for the detection of a 22-mer oligonucleotides sequence in Human Papillomavirus 18 virus (HPV18) gene. For this purpose, water-soluble CdTe quantum dots (QDs) were synthesized and, subsequently, amino-modified 11-mer oligonucleotide as one of the two necessary probes was attached to QDs surface to form functional QDs-DNA conjugates. Right after addition of the QDs-DNA and a second Cyanine5 (Cy5)-labeled 11-mer oligonucleotide probe to the DNA target solution, the sandwiched hybrids were formed. The resulting hybridization brings the Cy5 fluorophore as the acceptor to close proximity of the QDs as donor, so that an effective transfer of energy from the excited QDs to the Cy5 probe would occur via FRET processing. The fluorescence intensity of Cy5 found to linearly enhance by increasing the DNA target concentration from 1.0 to 50.0nM, with a detection limit of 0.2nM. This homogeneous DNA detection method does not require excessive washing and separation steps of un-hybridized DNA, due to the fact that no FRET can be observed when the probes are not ligated. Finally, feasibility and selectivity of the proposed one-spot DNA detection nanobiosensor were investigated by analysis of derived nucleotides from HPV18 and mismatched sequences.

Для цитирования: Shamsipur Mojtaba, Nasirian Vahid, Mansouri Kamran, Barati Ali, Veisi-Raygani Asad, Kashanian Soheila. A highly sensitive quantum dots-DNA nanobiosensor based on fluorescence resonance energy transfer for rapid detection of nanomolar amounts of human papillomavirus 18.. Journal of pharmaceutical and biomedical analysis. 2017. DOI: 10.1016/j.jpba.2017.01.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.