MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/20556683221094480

Медицинская библиотека · Journal of rehabilitation and assistive technologies engineering · 2022

Survey-based identification of design requirements and constraints for a wearable tremor suppression device.

Zhou Yue, Box Devin, Hardy Kenneth G, Jenkins Mary E, Garland Jayne, Naish Michael D, Trejos Ana Luisa

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Parkinsonian tremor has severely impacted the lives of 65% of individuals with Parkinson's disease, and nearly 25% do not respond to traditional treatments. Although wearable tremor suppression devices (WTSDs) have become a promising alternative approach, this technology is still in the early stages of development, and no studies have reported the stakeholders' opinions on this technology and their desired design requirements.

METHODS

An online survey was distributed to affected Canadians and Canadian movement disorder specialists (MDS) to acquire information on demographics, the current state of treatments, opinions on the WTSDs, and the desired design requirements of future WTSDs.

RESULTS

A total of 101 affected individuals and 24 MDS completed the survey. It was found that both groups are generally open to using WTSDs to manage tremor. The most important design requirement to end users is the adaptability to lifestyle, followed by weight and size, accurate motion, comfort, safety, quick response, and cost. Lastly, most of the participants (65%) think that the device should cost under $500.

CONCLUSIONS

The findings from this study can be used as guidelines for the development of future WTSDs, such that the future generations could be evaluated and accepted by the end users.

Для цитирования: Zhou Yue, Box Devin, Hardy Kenneth G, Jenkins Mary E, Garland Jayne, Naish Michael D, Trejos Ana Luisa. Survey-based identification of design requirements and constraints for a wearable tremor suppression device.. Journal of rehabilitation and assistive technologies engineering. 2022. DOI: 10.1177/20556683221094480.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…