Clinically Diagnose Asthma and Monitor Its Severity Using an Ultrasensitive Chemiresistive Nitric Oxide (NO) Gas Sensor via Exhaled Breath Analysis Assisted by Pattern Recognition.

Yin Peisi, You Xiaoyu, Cui Xinyue, Tang Zhipeng, Yu Shanshan, Fu Huaian, Song Fei, Zhang Kai, Zhao Xin, Wang Lipeng, Tian Huanhuan, Feng Xiaoyu, Li Ping, Liu Jinping, Zhai Nailiang, Jing Qiang, Han Shasha, Liu Bo

СтатьяПеревод в очереди

Аннотация

Fractional exhaled nitric oxide (FeNO) is widely recognized as a reliable biomarker for asthma. FeNO sensors can help diagnose asthma and monitor its severity. In this study, an ultrasensitive chemiresistive gas sensor, sensitive to the key breath biomarkers of asthma─nitric oxide (NO) and H2S─was fabricated using Ag-decorated ZnO. The sensor exhibits detection limits of 5 ppb for NO and 50 ppb for H2S, and it can discriminate 10 ppb NO and 60 ppb H2S from the exhaled breaths. Clinically, a total of 80 exhaled breath samples were collected and tested, including 40 from asthma patients (APs) and 40 from healthy control subjects (HCs). The AP group was effectively distinguished from the HC group using a pattern recognition algorithm (PCA), attributed to the sensor's beneficial cross-sensitivity to asthma biomarkers. A diagnostic model distinguishing asthma from non-asthma was constructed using the support vector machine (SVM) algorithm, achieving an overall accuracy, sensitivity, and specificity of 0.81, 0.88, and 0.75, respectively. The area under the curve (AUC) value for all subjects in the receiver operating characteristic (ROC) curve was 0.92. The severity of asthma in three inpatients was monitored using the clinical evaluation method of diurnal peak expiratory flow (PEF) variation, alongside our sensor. The sensor's response values exhibited a strong correlation (r = -0.74 (p < 0.05)) with the diurnal PEF variation values. To validate the sensor's diagnostic capability, six breath samples from both HCs and APs were tested simultaneously using our sensor and a commercial electrochemical NO sensor utilized clinically. With r = -0.98 (p < 0.05) and R2 = 0.94, a strong linear relationship between two types of response values was observed, confirming the sensor's accuracy and reliability in detecting NO concentrations in exhaled breath. Theoretical adsorption models of NO on the surface of the sensor were constructed using DFT calculations to elucidate the mechanisms driving the sensor's ultrasensitivity. Overall, the sensor demonstrates a significant potential for use in clinical practice to diagnose asthma and monitor its severity.

Для цитирования: Yin Peisi, You Xiaoyu, Cui Xinyue, Tang Zhipeng, Yu Shanshan, Fu Huaian, Song Fei, Zhang Kai, Zhao Xin, Wang Lipeng, Tian Huanhuan, Feng Xiaoyu, Li Ping, Liu Jinping, Zhai Nailiang, Jing Qiang, Han Shasha, Liu Bo. Clinically Diagnose Asthma and Monitor Its Severity Using an Ultrasensitive Chemiresistive Nitric Oxide (NO) Gas Sensor via Exhaled Breath Analysis Assisted by Pattern Recognition.. ACS sensors. 2025. DOI: 10.1021/acssensors.5c00772.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.