DOI 10.23736/s2724-5683.20.05138-5
Outcomes of the novolimus-eluting bioresorbable vascular scaffold in real world clinical practice.
Аннотация
BACKGROUND
Most of the current data regarding the use of bioresorbable scaffolds (BRS) come from everolimus-eluting stent platforms. Adverse events with the everolimus-eluting BRSs which are the most comprehensively characterized BRS, hampered the clinical use of other BRS. There is paucity of published data regarding long term use of novolimus-eluting BRS.
METHODS
This study sought to evaluate the performance of novolimus-eluting BRS device at midterm follow-up in real world clinical practice. One hundred and forty-four patients (mean age 57.5±9.7 years, 78.5% male) treated with 206 scaffolds between October 2015 and December 2017 were enrolled. A device-oriented composite endpoint (DOCE) comprising cardiac death, target vessel myocardial infarction (TV-MI), clinically driven target lesion revascularization (TLR) and rate of scaffold thrombosis were investigated.
RESULTS
During a mean follow-up of 33±9 months, DOCE occurred in 9 patients (6.3%) of which cardiac death occurred in 2 patients (1.4%), and clinically driven TLR in 7 patients (4.9%), TV-MI in one patient. Target vessel revascularization (TVR) was observed in nine patients. None of the patients experienced scaffold thrombosis.
CONCLUSIONS
The use of novolimus-eluting BRS in this real-world population achieved good clinical outcomes.