DOI 10.3760/cma.j.issn.1001-9391.2016.11.023
[Determination of relative elements of hard metal in workplace air and urine by inductive coupled plama].
Аннотация
Objective
To establish a rapid detection method regarding the air conditions of workplace and the workers' urine included Tungsten, Cobalt, Nickel, Titanium, Cadmium, Manganese, Lead and its compounds based on inductively coupled plasma mass spectrometry (ICP-MS) .
Methods
The experiment adopts ICP-MS to deter-mine those metals in workshop air and workers urine, evaluate the detection's limitation, the precision and accuracy of the method. Using the membrane filter and urine freeze - dried metal standard material to verify this method.
Results
Each element of correlation coefficient was greater than 0.999. The recovery rate of air samples was 91.6%~104.6%, within-batch RSD precision was 1.41%~3.50%, between-run precision was 1.28%~4.31%, urine samples recovery rate was 93.0%~102.6%, within - batch RSD precision was 1.25%~3.56%, between - run precision was 1.58%~4.67%, According to the method every element was within the scope of the standard reference, it was also showed that the established method is accurate and reliable.
Conclusion
ICP-MS is an effective and feasible method to detect the workshop air and the workers' urine which included Tungsten, Cobalt, Nickel, Titanium, Cadmium, Manganese, Lead and its compounds.