MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.crad.2014.03.009

Медицинская библиотека · Clinical radiology · 2014

Cardiothoracic ratio may be misleading in the assessment of right- and left-ventricular size in patients with repaired tetralogy of Fallot.

Spiewak M, Małek L A, Biernacka E K, Kowalski M, Michałowska I, Hoffman P, Miśko J, Demkow M, Rużyłło W, Marczak M

СтатьяПеревод в очереди

Аннотация

AIM: To assess the relationship between cardiothoracic ratio (CTR) and ventricular and atrial volumes in patients with repaired tetralogy of Fallot (TOF).

MATERIALS AND

METHODS

Patients with repaired TOF undergoing cardiac magnetic resonance (CMR) and chest radiography within 1 day were included (n = 82; median age: 24.7 years, interquartile range: 21.5-35.9). The CTR was obtained from upright posteroanterior chest roentgenograms. Analyses of CMR images and radiographs were performed in a blinded fashion.

RESULTS

There were 35.1% (13/37) of patients with normal CTR (<0.5) who had severe right ventricular (RV) dilatation. There were six patients (13.3%, 6/45) with high CTR with both normal RV and left-ventricular (LV) volumes. CTR did not correlate with either RV or LV volumes but showed a weak correlation with right- and left-atrial volumes (r = 0.43, p = 0.0001; r = 0.27, p = 0.01, respectively). CTR ≥0.5 showed poor ability in the identification of severe RV dilatation (sensitivity: 61.8%, specificity: 50%). The combination of CTR and signs of RV enlargement on lateral radiographs did not improve the diagnostic accuracy of any of those parameters alone.

CONCLUSION

CTR in patients with repaired TOF reflected atrial rather than ventricular dilatation. The use of CTR or lateral radiographs in patients with repaired TOF may lead to false conclusions concerning ventricular size.

Для цитирования: Spiewak M, Małek L A, Biernacka E K, Kowalski M, Michałowska I, Hoffman P, Miśko J, Demkow M, Rużyłło W, Marczak M. Cardiothoracic ratio may be misleading in the assessment of right- and left-ventricular size in patients with repaired tetralogy of Fallot.. Clinical radiology. 2014. DOI: 10.1016/j.crad.2014.03.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.