High-performance liquid chromatographic determination of naltrexone in plasma of hemodialysis patients.

Kambia K, Bah S, Dine T, Azar R, Odou P, Gressier B, Luyckx M, Brunet C, Ballester L, Cazin M, Cazin J C

СтатьяПеревод в очереди

Аннотация

A simple, sensitive, selective and reliable reversed-phase high-performance liquid chromatographic (HPLC) method with UV detection is described for the determination of naltrexone in plasma samples. Naltrexone and the internal standard, naloxone, were isolated from plasma either with a liquid-liquid extraction method using ethyl acetate or with a solid-phase extraction method using Sep-Pack C18 cartridge before chromatography. The extracts were dried under a stream of nitrogen and the samples were reconstituted in the mobile phase, then 20 microL were injected on a Waters Symmetry C18 column (5 microm particle size, 4.6 x 150 mm). The mobile phase consisted of 0.06% triethylamine (pH 2.8)-acetonitrile (92:8, v/v) pumped at 1 mL/min. The peak-area ratio versus plasma concentration was linear over the range of 10-500 ng/mL and the detection limit was less than 8 ng/mL. Quantification was by ultra-violet detection at 204 nm. The present method was applied to the determination of the plasma concentration of naltrexone in dialyzed patients. Patients (n = 8) with severe generalized pruritus received 50 mg of naltrexone orally per day for 2 weeks. The variability in the therapeutic response in treated patients required plasma concentration investigations of this opioid antagonist.

Для цитирования: Kambia K, Bah S, Dine T, Azar R, Odou P, Gressier B, Luyckx M, Brunet C, Ballester L, Cazin M, Cazin J C. High-performance liquid chromatographic determination of naltrexone in plasma of hemodialysis patients.. Biomedical chromatography : BMC. 2000. DOI: 10.1002/1099-0801(200005)14:3<151::aid-bmc941>3.0.co;2-e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.