Post Melody valve implant in a conduit with regurgitant native outflow tract successful closure by Amplatzer muscular device.

Momenah Tarek S, El Houry Motea T, Khan Muhammad A, Galal Mohammed O

Клинический случайСтатьяПеревод в очереди

Аннотация

We describe the technique of closure of native right ventricular outflow tract by Amplatzer muscular ventricular septal defect device because of severe regurgitation in a patient who had tetralogy of Fallot repair with conduit at 3 years of age followed by percutaneous Melody valve implant 6 years later.

Для цитирования: Momenah Tarek S, El Houry Motea T, Khan Muhammad A, Galal Mohammed O. Post Melody valve implant in a conduit with regurgitant native outflow tract successful closure by Amplatzer muscular device.. Cardiology in the young. 2014. DOI: 10.1017/s1047951113002357.