MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2008.08.015

Медицинская библиотека · Journal of chromatography. A · 2008

Preparation of an open-tubular capillary column with a monolithic layer of S-ketoprofen imprinted and 4-styrenesulfonic acid incorporated polymer and its enhanced chiral separation performance in capillary electrochromatography.

Zaidi Shabi Abbas, Cheong Won Jo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Enhanced chiral separation performance has been observed for ketoprofen enantiomers in capillary electrochromatography (CEC) with an open-tubular (OT) column prepared with a specific molecule imprinted polymer (MIP) on the innerwall of 50mum ID capillary. The column was prepared by in situ thermal polymerization inside the pretreated and silanized fused silica capillary. A specific diluted monomer mixture composed of S-ketoprofen, methacrylic acid (MAA, functional monomer), ethylene glycol dimethacrylate (EDMA, cross-linker), and 4-styrenesulfonic acid (4-SSA) dissolved in 9/1 (v/v) acetonitrile/2-propanol was used to fabricate the OT-MIP layer. 4-SSA was added to form a MIP layer capable of stable and strong electro-osmotic flow (EOF) over the pH range of this study securing CEC elution of ketoprofen having partial negative charge near the optimized pH. Various parameters such as buffer pH, organic modifier composition, salt concentration, and applied potential have been optimized for CEC chiral separation of ketoprofen enantiomers. Very good separation selectivity and efficiency were observed, thus the chromatographic resolution of ketoprofen enantiomers was as high as 10.5, and the number of theoretical plates of R-ketoprofen, 156,000/m (40,000/m for S-ketoprofen), which proves that the OT-MIP-CEC type approach is a promising strategy in MIP study.

Для цитирования: Zaidi Shabi Abbas, Cheong Won Jo. Preparation of an open-tubular capillary column with a monolithic layer of S-ketoprofen imprinted and 4-styrenesulfonic acid incorporated polymer and its enhanced chiral separation performance in capillary electrochromatography.. Journal of chromatography. A. 2008. DOI: 10.1016/j.chroma.2008.08.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.