MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.msec.2012.11.005

Медицинская библиотека · Materials science & engineering. C, Materials for biological applications · 2012

Highly selective and sensitive voltammetric sensor based on modified multiwall carbon nanotube paste electrode for simultaneous determination of ascorbic acid, acetaminophen and tryptophan.

Keyvanfard Mohsen, Shakeri Razieh, Karimi-Maleh Hassan, Alizad Khadijeh

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A carbon-paste electrode modified with multiwall carbon nanotubes (MWCNTs) was used for the sensitive and selective voltammetric determination of ascorbic acid (AA) in the presence of 3,4-dihydroxycinnamic acid (3,4-DHCA) as mediator. The mediated oxidation of AA at the modified electrode was investigated by cyclic voltammetry (CV), chronoamperommetry and electrochemical impedance spectroscopy (EIS). Also, the values of catalytic rate constant (k), and diffusion coefficient (D) for AA were calculated. Using square wave voltammetry (SWV), a highly selective and simultaneous determination of AA, acetaminophen (AC) and tryptophan (Trp) has been explored at the modified electrode. The modified electrode displayed strong function for resolving the overlapping voltammetric responses of AA, AC and Trp into three well-defined voltammetric peaks. In the mixture containing AA, AC and Trp, the three compounds can well separate from each other with potential differences of 200, 330 and 530 mV between AA and AC, AC and Trp and AA and Trp, respectively, which was large enough to determine AA, AC and Trp individually and simultaneously.

Для цитирования: Keyvanfard Mohsen, Shakeri Razieh, Karimi-Maleh Hassan, Alizad Khadijeh. Highly selective and sensitive voltammetric sensor based on modified multiwall carbon nanotube paste electrode for simultaneous determination of ascorbic acid, acetaminophen and tryptophan.. Materials science & engineering. C, Materials for biological applications. 2012. DOI: 10.1016/j.msec.2012.11.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.