MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0038-1676616

Медицинская библиотека · American journal of perinatology · 2018

Variation in Cervical Length over Time during a Single Transvaginal Ultrasound Examination.

Connolly Katherine A, Vieira Luciana, Yoselevsky Elizabeth M, Pan Stephanie, Stone Joanne L

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To quantify the degree of change in cervical length (CL) over a 3-minute transvaginal ultrasound.

STUDY

DESIGN

We conducted a prospective observational study of nulliparous patients who underwent routine transvaginal CL screening at the time of their second-trimester ultrasound. We recorded CL at four time points (0, 1, 2, 3 minutes) and compared these values to determine the minute-to-minute change within a single patient.

RESULTS

A total of 771 patients were included. The mean gestational age was 20.8 weeks (±0.84). We used a linear mixed effect model to assess if each minute during the ultrasound is associated with a change in CL. The intraclass correlation coefficient between minute 0 to minute 3 was 0.82 (95% confidence interval: 0.80, 0.84). This indicates that there is a relatively high within-patient correlation in CL during their ultrasound. Additionally, we stratified patients based on their starting CL; the intraclass correlation coefficient remained high for all groups. We additionally compared CL at each minute. Although there is a statistically significant difference between several time points, the actual difference is small and not clinically meaningful.

CONCLUSION

The variation in CL over a 3-minute transvaginal ultrasound examination is not clinically significant. It may be reasonable to conduct this examination over a shorter period.

Для цитирования: Connolly Katherine A, Vieira Luciana, Yoselevsky Elizabeth M, Pan Stephanie, Stone Joanne L. Variation in Cervical Length over Time during a Single Transvaginal Ultrasound Examination.. American journal of perinatology. 2018. DOI: 10.1055/s-0038-1676616.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.