MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2024.07.002

Медицинская библиотека · JACC. Clinical electrophysiology · 2024

Optimizing the Distribution of Ablation Lesions to Prevent Postablation Atrial Tachycardia: A Personalized Digital-Twin Study.

Sakata Kensuke, Bradley Ryan P, Prakosa Adityo, Yamamoto Carolyna A P, Yusuf Ali Syed, Loeffler Shane, Kholmovski Eugene G, Kumar Sinha Sunil, Marine Joseph E, Calkins Hugh, Spragg David D, Trayanova Natalia A

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Although targeting atrial fibrillation (AF) drivers and substrates has been used as an effective adjunctive ablation strategy for patients with persistent AF (PsAF), it can result in iatrogenic scar-related atrial tachycardia (iAT) requiring additional ablation. Personalized atrial digital twins (DTs) have been used preprocedurally to devise ablation targeting that eliminate the fibrotic substrate arrhythmogenic propensity and could potentially be used to predict and prevent postablation iAT.

OBJECTIVES

In this study, the authors sought to explore possible alternative configurations of ablation lesions that could prevent iAT occurrence with the use of biatrial DTs of prospectively enrolled PsAF patients.

METHODS

Biatrial DTs were generated from late gadolinium enhancement-magnetic resonance images of 37 consecutive PsAF patients, and the fibrotic substrate locations in the DT capable of sustaining reentries were determined. These locations were ablated in DTs by representing a single compound region of ablation with normal power (SSA), and postablation iAT occurrence was determined. At locations of iAT, ablation at the same DT target was repeated, but applying multiple lesions of reduced-strength (MRA) instead of SSA.

RESULTS

Eighty-three locations in the fibrotic substrates of 28 personalized biatrial DTs were capable of sustaining reentries and were thus targeted for SSA ablation. Of these ablations, 45 resulted in iAT. Repeating the ablation at these targets with MRA instead of SSA resulted in the prevention of iAT occurrence at 15 locations (18% reduction in the rate of iAT occurrence).

CONCLUSIONS

Personalized atrial DTs enable preprocedure prediction of iAT occurrence after ablation in the fibrotic substrate. It also suggests MRA could be a potential strategy for preventing postablation AT.

Для цитирования: Sakata Kensuke, Bradley Ryan P, Prakosa Adityo, Yamamoto Carolyna A P, Yusuf Ali Syed, Loeffler Shane, Kholmovski Eugene G, Kumar Sinha Sunil, Marine Joseph E, Calkins Hugh, Spragg David D, Trayanova Natalia A. Optimizing the Distribution of Ablation Lesions to Prevent Postablation Atrial Tachycardia: A Personalized Digital-Twin Study.. JACC. Clinical electrophysiology. 2024. DOI: 10.1016/j.jacep.2024.07.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.