MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12880-025-01797-9

Медицинская библиотека · BMC medical imaging · 2025

Automated 3D segmentation of the hyoid bone in CBCT using nnU-Net v2: a retrospective study on model performance and potential clinical utility.

Gümüssoy Ismail, Haylaz Emre, Duman Suayip Burak, Kalabalik Fahrettin, Say Seyda, Celik Ozer, Bayrakdar Ibrahim Sevki

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study aimed to identify the hyoid bone (HB) using the nnU-Net based artificial intelligence (AI) model in cone beam computed tomography (CBCT) images and assess the model's success in automatic segmentation.

METHODS

CBCT images of 190 patients were randomly selected. The raw data was converted to DICOM format and transferred to the 3D Slicer Imaging Software (Version 4.10.2; MIT, Cambridge, MA, USA). HB was labeled manually using the 3D Slicer. The dataset was divided into training, validation, and test sets in a ratio of 8:1:1. The nnU-Net v2 architecture was utilized to process the training and test datasets, generating the algorithm weight factors. To assess the model's accuracy and performance, a confusion matrix was employed. F1-score, Dice coefficient (DC), 95% Hausdorff distance (95% HD), and Intersection over Union (IoU) metrics were calculated to evaluate the results.

RESULTS

The model's performance metrics were as follows: DC = 0.9434, IoU = 0.8941, F1-score = 0.9446, and 95% HD = 1.9998. The receiver operating characteristic (ROC) curve was generated, yielding an AUC value of 0.98.

CONCLUSION

The results indicated that the nnU-Net v2 model achieved high precision and accuracy in HB segmentation on CBCT images. Automatic segmentation of HB can enhance clinicians' decision-making speed and accuracy in diagnosing and treating various clinical conditions.

CLINICAL TRIAL NUMBER: Not applicable.

Для цитирования: Gümüssoy Ismail, Haylaz Emre, Duman Suayip Burak, Kalabalik Fahrettin, Say Seyda, Celik Ozer, Bayrakdar Ibrahim Sevki. Automated 3D segmentation of the hyoid bone in CBCT using nnU-Net v2: a retrospective study on model performance and potential clinical utility.. BMC medical imaging. 2025. DOI: 10.1186/s12880-025-01797-9.