MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-022-02968-9

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022

Rest/stress myocardial perfusion imaging by positron emission tomography with 18F-Flurpiridaz: A feasibility study in mice.

Bengs Susan, Warnock Geoffrey I, Portmann Angela, Mikail Nidaa, Rossi Alexia, Ahmed Hazem, Etter Dominik, Treyer Valerie, Gisler Livio, Pfister Stefanie K, Jie Caitlin V M L, Meisel Alexander, Keller Claudia, Liang Steven H, Schibli Roger, Mu Linjing, Buechel Ronny R, Kaufmann Philipp A, Ametamey Simon M, Gebhard Catherine, Haider Achi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Myocardial perfusion imaging by positron emission tomography (PET-MPI) is the current gold standard for quantification of myocardial blood flow. 18F-flurpiridaz was recently introduced as a valid alternative to currently used PET-MPI probes. Nonetheless, optimum scan duration and time interval for image analysis are currently unknown. Further, it is unclear whether rest/stress PET-MPI with 18F-flurpiridaz is feasible in mice.

METHODS

Rest/stress PET-MPI was performed with 18F-flurpiridaz (0.6-3.0 MBq) in 27 mice aged 7-8 months. Regadenoson (0.1 µg/g) was used for induction of vasodilator stress. Kinetic modeling was performed using a metabolite-corrected arterial input function. Image-derived myocardial 18F-flurpiridaz uptake was assessed for different time intervals by placing a volume of interest in the left ventricular myocardium.

RESULTS

Tracer kinetics were best described by a two-tissue compartment model. K1 ranged from 6.7 to 20.0 mL·cm-3·min-1, while myocardial volumes of distribution (VT) were between 34.6 and 83.6 mL·cm-3. Of note, myocardial 18F-flurpiridaz uptake (%ID/g) was significantly correlated with K1 at rest and following pharmacological vasodilation for all time intervals assessed. However, while Spearman's coefficients (rs) ranged between 0.478 and 0.681, R2 values were generally low. In contrast, an excellent correlation of myocardial 18F-flurpiridaz uptake with VT was obtained, particularly when employing the averaged myocardial uptake from 20 to 40 min post tracer injection (R2 ≥ 0.98). Notably, K1 and VT were similarly sensitive to pharmacological vasodilation induction. Further, mean stress-to-rest ratios of K1, VT, and %ID/g 18F-flurpiridaz were virtually identical, suggesting that %ID/g 18F-flurpiridaz can be used to estimate coronary flow reserve (CFR) in mice.

CONCLUSION

Our findings suggest that a simplified assessment of relative myocardial perfusion and CFR, based on image-derived tracer uptake, is feasible with 18F-flurpiridaz in mice, enabling high-throughput mechanistic CFR studies in rodents.

Для цитирования: Bengs Susan, Warnock Geoffrey I, Portmann Angela, Mikail Nidaa, Rossi Alexia, Ahmed Hazem, Etter Dominik, Treyer Valerie, Gisler Livio, Pfister Stefanie K, Jie Caitlin V M L, Meisel Alexander, Keller Claudia, Liang Steven H, Schibli Roger, Mu Linjing, Buechel Ronny R, Kaufmann Philipp A, Ametamey Simon M, Gebhard Catherine, Haider Achi. Rest/stress myocardial perfusion imaging by positron emission tomography with 18F-Flurpiridaz: A feasibility study in mice.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2022. DOI: 10.1007/s12350-022-02968-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.