Flushing Versus Pushing Technique for Graft Implantation in Descemet Membrane Endothelial Keratoplasty.

Siebelmann Sebastian, Janetzko Mona, König Peter, Scholz Paula, Matthaei Mario, Händel Alexander, Cursiefen Claus, Bachmann Björn

СтатьяПеревод в очереди

Аннотация

PURPOSE: Descemet membrane endothelial keratoplasty (DMEK) has developed into a safe procedure for the replacement of diseased corneal endothelium. However, DMEK still results in a significant donor endothelial cell loss. Here, we compare 2 different graft implantation techniques.

METHODS

Twenty patients undergoing DMEK, where a DMEK injection cartridge was used to flush the graft into the anterior chamber (G-38635 single-use DMEK-Cartridge; Geuder AG, Heidelberg, Germany; group A), were retrospectively compared with 20 patients, where a standard lens injection cartridge (AT.Smart Cartridge; Carl Zeiss Meditec AG, Jena, Germany; group B) was used to push the graft with a plunger. Outcome parameters were intraoperative orientation of the graft, insertion-to-attachment time, rebubbling rates, and postoperative best spectacle-corrected visual acuity, endothelial cell count, and central corneal thickness after 12 months. The surfaces of both cartridges were evaluated by scanning electron microscopy.

RESULTS

In group A, the insertion-to-attachment time was significantly higher (P = 0.003). Initially, the graft was oriented correctly in 40% of the patients in group A compared with 90% in group B (P = 0.001). No differences were obtained between both groups regarding central corneal thickness, endothelial cell count or best spectacle-corrected visual acuity, and rebubbling rates after 12 months. Scanning electron microscopy analysis demonstrated a rougher and sharper surface of the shooter of group B.

CONCLUSIONS

This study shows significant differences between both insertion techniques regarding correct graft orientation directly after graft implantation leading to prolonged insertion-to-attachment time when the graft is flushed instead of pushed into the anterior chamber.

Для цитирования: Siebelmann Sebastian, Janetzko Mona, König Peter, Scholz Paula, Matthaei Mario, Händel Alexander, Cursiefen Claus, Bachmann Björn. Flushing Versus Pushing Technique for Graft Implantation in Descemet Membrane Endothelial Keratoplasty.. Cornea. 2020. DOI: 10.1097/ico.0000000000002239.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.