Autoimmune encephalitis with anti-IgLON5 and anti-GABAB-receptor antibodies: A case report.

Chung Ha-Yeun, Wickel Jonathan, Voss Annika, Ceanga Mihai, Sell Josefine, Witte Otto W, Geis Christian

Клинический случайСтатьяПеревод в очереди

Аннотация

RATIONALE: Anti-IgLON5 disease is a complex neurological illness which is characterized by progressive sleep and movement disorders and defined by specific autoantibodies to IgLON5. We here describe the first case of a patient with coexisting anti-IgLON5 as well as anti-γ-aminobutyric acid B (GABAB)-receptor antibodies and predominant clinical features of anti-IgLON5 disease.

PATIENT CONCERNS: The patient initially presented with subacute symptoms of severe sleep disorder, gait stability, dysarthria, cognitive impairment, depressive episode and hallucinations.

DIAGNOSES: The patient was diagnosed with autoimmune encephalitis, based on clinical features and positive anti-IgLON5 antibodies in serum as well as in cerebrospinal fluid and anti-GABAB-receptor antibodies in serum only.

INTERVENTIONS: Initially, the patient was treated with high dosages of methylprednisolone and subsequently with plasmapheresis. Due to the lack of clinical improvement immunosuppressive treatment with intravenous cyclophosphamide was initiated.

OUTCOMES: Following the first year of cyclophosphamide treatment, neurological examination revealed an improvement in gait instability, visual and acoustic hallucinations and sleep disorder.

LESSONS: The case report demonstrates that anti-IgLON5 and anti-GABAB-receptor antibodies can coexist in the same patient whereas clinical leading symptoms are determined by those antibodies that were tested positive in cerebrospinal fluid.

Для цитирования: Chung Ha-Yeun, Wickel Jonathan, Voss Annika, Ceanga Mihai, Sell Josefine, Witte Otto W, Geis Christian. Autoimmune encephalitis with anti-IgLON5 and anti-GABAB-receptor antibodies: A case report.. Medicine. 2019. DOI: 10.1097/md.0000000000015706.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.