DOI 10.1088/0967-3334/23/1/323

Медицинская библиотека · Physiological measurement · 2002

Imaging the breast with EIS: an initial study of exam consistency.

Kerne Todd E, Hartov Alex, Soho Sandra K, Poplack Steven P, Paulsen Keith D

Клиническое исследованиеСтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

Use of electrical impedance spectroscopy (EIS) to image the breasts of women with both normal and abnormal conditions requires the ability to deliver a consistent and repeatable exam. To investigate the degree to which our current imaging system can meet this requirement we conducted an initial study of exam consistency. The trial involved the imaging of 25 breasts stratified into four separate substudies with increasing levels of electrode placement uncertainty. The degree of complexity ranged from single-placement single-session imaging to multiple-placement single-session imaging to multiple-placement multiple-session imaging. Both visual analysis and quantitative comparisons using mean squared difference (MSD) measures between pairs of permittivity and conductivity images were performed. A new breast interface with the improved vertical and radial electrode array positioning capability required to complete this study is described. Not surprisingly, the results show a dominant trend of increased image variability with increased electrode placement uncertainty. Importantly, quantitative levels of image consistency are reported through MSD analysis. On average across all frequencies analysed, MSDs for single placements are well below 1%, near 2-3% for repositioned breasts during the same session and approximately 15% for re-examined breasts in multiple sessions conducted over time. Overall, these results suggest that EIS breast exams are consistent provided the electrode placement is well controlled, typically with better than 1 cm accuracy.

Для цитирования: Kerne Todd E, Hartov Alex, Soho Sandra K, Poplack Steven P, Paulsen Keith D. Imaging the breast with EIS: an initial study of exam consistency.. Physiological measurement. 2002. DOI: 10.1088/0967-3334/23/1/323.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.