MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/smll.202307764

Медицинская библиотека · Small (Weinheim an der Bergstrasse, Germany) · 2024

Efficient Photothermal Sensor Based on Coral-Like Hollow Gold Nanospheres for the Sensitive Detection of Sulfonamides.

Xiao Xiaoyue, Yu Sha, Zhang Gan, Chen Zongyou, Hu Hong, Lai Xiaocui, Liu Daofeng, Lai Weihua

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Gold nanoparticles (AuNPs), universally regarded as colorimetric signal reporters, are widely employed in lateral flow immunoassays (LFIAs). However, it is difficult for AuNPs-LFIA to achieve a wide range and sensitive detection. Herein, novel coral-like hollow gold nanospheres (CHGNPs) are synthesized. The growth of gold nanospheres can be regulated to obtain a multibranched and hollow construction. The obtained CHGNPs possess intense broadband absorption across the visible to near-infrared region, exhibiting a high molar extinction coefficient of 14.65 × 1011 M-1 cm-1 and a photothermal conversion efficiency of 79.75%. Thus, the photothermal/colorimetric dual-readout LFIA is developed based on CHGNPs (CHGNPs-PT-LFIA and CHGNPs-CM-LFIA) to effectively improve the detection sensitivity and broaden the detection range in regard to sulfonamides (SAs). The limits of detection of the CHGNPs-PT-LFIA and CHGNPs-CM-LFIA reached 1.9 and 2.8 pg mL-1 for the quantitative detection of sulfaquinoxaline, respectively, which are 6.3-fold and 4.3-fold lower than that of the AuNPs-LFIA. Meanwhile, the CHGNPs-PT-LFIA broadened the detection range to three orders of magnitude, which ranged from 2.5 to 5000 pg mL-1. The synthesized photothermal CHGNPs have been proven effective in improving the performance of the LFIA and provide a potential option for the construction of sensing platforms.

Для цитирования: Xiao Xiaoyue, Yu Sha, Zhang Gan, Chen Zongyou, Hu Hong, Lai Xiaocui, Liu Daofeng, Lai Weihua. Efficient Photothermal Sensor Based on Coral-Like Hollow Gold Nanospheres for the Sensitive Detection of Sulfonamides.. Small (Weinheim an der Bergstrasse, Germany). 2024. DOI: 10.1002/smll.202307764.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.