Медицинская библиотека · Techniques in hand & upper extremity surgery · 2004

The pi plate: an implant for unstable extension fractures of the distal radius in patients with osteoporotic bone.

Keller Martin, Steiger Regula

СтатьяПеревод в очереди

Аннотация

Extension fractures of the distal radius are very common injuries in elderly women caused by moderate energy trauma. Nevertheless there is no consensus about how these fractures should be treated. Anatomic reduction of the distal radius is necessary to achieve good functional results. In particular, the elderly patient, who may have to use crutches or a walker, will need a pain-free wrist under axial load. The pi plate is designed for distal radius fractures. It has been widely criticized for causing irritation and/or rupture of the extensor tendons. Most complications of the implant can be avoided with a careful operative technique. To prevent ruptures of the extensor tendon implant removal after 4 to 6 months is recommended. In osteoporotic bone the pi plate guarantees good stability with minimal postoperative loss of reduction. The operative technique is described in detail and common complications are discussed.

Для цитирования: Keller Martin, Steiger Regula. The pi plate: an implant for unstable extension fractures of the distal radius in patients with osteoporotic bone.. Techniques in hand & upper extremity surgery. 2004. DOI: 10.1097/00130911-200412000-00003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.