Concordance of breast imaging reporting and data system assessments and management recommendations in screening mammography.
Аннотация
PURPOSE: To examine how frequently Breast Imaging Reporting and Data System (BI-RADS) mammographic screening assessments were associated with expected clinical management recommendations.
MATERIALS AND
METHODS
Seven Breast Cancer Surveillance Consortium mammography registries recorded screening assessments and recommendations in 1997 to identify the proportion of women in each BI-RADS category. The first screening assessment for a woman without cancer or a prior mammogram within 9 months was associated with its independently recorded recommendation.
RESULTS
Among 292,795 women, screening assessments included 269,022 (91.9%) with a "negative" or "benign finding," and 267,103 (99.3%) of these women were recommended for normal interval follow-up. Among 11,861 (4.1%) women with screening assessments of "probably benign finding," 4,782 (40.3%) were recommended for short interval follow-up as expected on the basis of the BI-RADS, but a high proportion (36.9%) were recommended for additional imaging. Among 1,625 (0.6%) women with "suspicious abnormality," most were recommended for biopsy (48.7%) or clinical examination and/or surgical consult (9.0%), but many were recommended for additional imaging (38.7%). Among 243 (0.1%) women with screening assessments "highly suggestive of malignancy," a majority were recommended for biopsy (73.3%) or clinical examination and/or surgical consult (18.1%) consistent with BI-RADS, but some were recommended for additional imaging (6.6%).
CONCLUSION
BI-RADS assessments and management recommendations are consistent for negative and benign assessments, but inconsistencies were found in assessments and recommendations for mammographic abnormalities.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.