DOI 10.1016/j.athoracsur.2008.09.032

Медицинская библиотека · The Annals of thoracic surgery · 2009

Midterm change of descending aortic false lumen after repair of acute type I dissection.

Park Kay-Hyun, Lim Cheong, Choi Jin Ho, Chung Euisuk, Choi Sang Il, Chun Eun Ju, Sung Kiick

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Persistent false lumen in the descending aorta after repair of acute type I dissection adversely affects long-term prognosis. In this study, we investigated changes of the descending aortic false lumen during the midterm postoperative period.

METHODS

Postoperative computed tomographic (CT) images of 122 patients who underwent conventional ascending with or without arch replacement for acute type I dissection were reviewed. Patency and width of false lumen and maximal diameter of the aorta were compared between early and last follow-up images. Changes were analyzed separately in the thoracic and abdominal segments.

RESULTS

In early CT, thoracic false lumen was patent in 85 patients (69.7%), and abdominal false lumen was patent in 111 patients (91.0%). Among these, the false lumen remained patent after a mean interval of 33.6 months in 69 patients (81.1%) and 105 patients (94.6%), respectively. In 58 patients (47.5%), the descending aorta dilated by 1 cm or more. Dilatation occurred more frequently in the thoracic aorta and in patients with patent or wide false lumens, larger aortic diameter, Marfan syndrome, younger age, and male sex. Meanwhile, shrinkage of thoracic false lumen occurred in 36 patients (29.5%). Such shrinkage occurred in 23 of 24 patients (95.8%) who had thrombosed and narrow false lumens in the thoracic aorta.

CONCLUSIONS

Early postoperative characteristics of false lumen were helpful for predicting both dilation and regression. Our data show not only a high incidence of descending aortic dilatation after repair of acute type I dissection, but also shrinkage of thoracic false lumen in some patients. These findings can be used as control data for determining the benefit of more extensive or new surgical approaches.

Для цитирования: Park Kay-Hyun, Lim Cheong, Choi Jin Ho, Chung Euisuk, Choi Sang Il, Chun Eun Ju, Sung Kiick. Midterm change of descending aortic false lumen after repair of acute type I dissection.. The Annals of thoracic surgery. 2009. DOI: 10.1016/j.athoracsur.2008.09.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.