Diagnostic accuracy of hysteroscopy in endometrial hyperplasia.

Loverro G, Bettocchi S, Cormio G, Nicolardi V, Porreca M R, Pansini N, Selvaggi L

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To determine the diagnostic accuracy of hysteroscopy in the diagnosis of endometrial hyperplasia in women with abnormal uterine bleeding.

METHODS

From 1993 through 1995, 980 women referred to our institution for abnormal uterine bleeding underwent diagnostic hysteroscopy with eye direct biopsy of the endometrium in case of macroscopic abnormalities. Hysteroscopic features were compared with pathologic findings in order to detect the reliability of the endoscopic procedure. Statistical analysis was performed with the McNemar test.

RESULTS

Positive predictive value of hysteroscopy in the diagnosis of endometrial hyperplasia accounted for 63%. In fact hysteroscopic diagnosis of endometrial hyperplasia was confirmed at pathologic examination in 81 out of 128 patients. Sensitivity and specificity of the endoscopic procedure accounted for 98% and 95%, respectively. Negative predictive value accounted for 99%, as only two cases of atypical hyperplasia were missed at hysteroscopy. Positive predictive value was higher in postmenopausal patients compared to women in the fertile age (72 vs. 58%).

CONCLUSIONS

Overall, results appear encouraging, since no case of endometrial hyperplasia was missed by hysteroscopy. The high diagnostic accuracy, associated with a minimal trauma, renders hysteroscopy the ideal procedure for both diagnosis and follow-up of conservative management of endometrial hyperplasia.

Для цитирования: Loverro G, Bettocchi S, Cormio G, Nicolardi V, Porreca M R, Pansini N, Selvaggi L. Diagnostic accuracy of hysteroscopy in endometrial hyperplasia.. Maturitas. 1996. DOI: 10.1016/s0378-5122(96)01064-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.