PURPOSE: To evaluate the accuracy of scintimammography as an adjunct to physical examination and mammography in the detection of breast cancer in women with dense and fatty breasts.

MATERIALS AND

METHODS

A total of 558 women were prospectively enrolled from 42 centers in North America. Images were interpreted by readers blinded to the subjects' clinical history, mammographic findings, and other test results. The Breast Imaging Reporting and Data System classification was used to describe breast density. Parenchymal patterns of "heterogeneously dense" and "extremely dense" were used to classify breasts as dense, whereas "almost entirely fat" and "numerous vague densities" defined fatty breasts. Between-group differences were evaluated with the 2 test for categorical variables and Student t test for continuous variables. Accuracy of scintimammography was assessed against the core laboratory histopathologic evaluation, the standard. The 95% CIs around point estimates of sensitivity, specificity, and positive and negative predictive values were calculated with the normal approximation to the binomial distribution.

RESULTS

The analyses were based on 580 breasts with an abnormality; 276 (48%) breasts were dense and 228 had a malignant lesion. Diagnostic properties for scintimammography of fatty versus dense breasts were, respectively, sensitivity, 72% versus 70%; specificity, 80% versus 78%; positive predictive value, 72% versus 67%; negative predictive value, 81% versus 81%; and accuracy, 77% versus 75% (all not significant). Scintimammography led to similar and significant changes in the posttest likelihood of cancer for both dense and fatty breasts.

CONCLUSION

The diagnostic accuracy of scintimammography is not affected by breast density.

Для цитирования: Khalkhali Iraj, Baum Janet K, Villanueva-Meyer Javier, Edell Steven L, Hanelin Laurence G, Lugo Carlos E, Taillefer Raymond, Freeman Leonard M, Neal Charles E, Scheff Alice M, Connolly James L, Schnitt Stuart J, Houlihan Mary J, Sampalis John S, Haber Stephen B. (99m)Tc sestamibi breast imaging for the examination of patients with dense and fatty breasts: multicenter study.. Radiology. 2002. DOI: 10.1148/radiol.2221010237.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.