Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia · 2021
Extraluminal Placement of a Bronchial Blocker Compared with Carbon Dioxide Artificial Pneumothorax in Infants Undergoing Video-Assisted Thoracoscopic Surgery.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wang Jing, Xie Wen-Peng, Lei Yu-Qing, Yu Ling-Shan, Wang Zeng-Chun, Cao Hua, Chen Qiang
Аннотация
OBJECTIVE: To investigate the safety and effectiveness of extraluminal placement of a bronchial blocker compared with carbon dioxide (CO2) artificial pneumothorax in infants undergoing video-assisted thoracoscopic surgery (VATS).
METHODS: The study involved 33 infants (group A) who underwent one-lung ventilation (OLV) with extraluminal placement of a bronchial blocker and 35 other infants (group B) who underwent CO2 artificial pneumothorax. Clinical characteristics, the degree of lung collapse, and complications were compared.
RESULTS: The degree of lung collapse in group A was significantly higher than that in group B at T2 and T3. The mean arterial pressure (MAP) of group B was significantly lower than that of group A at 10 min and 30 min after OLV. The partial pressure of carbon dioxide (PaCO2) of group B was significantly higher than that of group A at 30 min after OLV. The incidence of hypotension in group B was higher than that in group A.
CONCLUSION: Compared with CO2 artificial pneumothorax, extraluminal placement of a bronchial blocker is associated with a better degree of lung collapse, fewer episodes of hypotension, and lower PaCO2 accumulation during OLV in infants undergoing VATS.
METHODS: The study involved 33 infants (group A) who underwent one-lung ventilation (OLV) with extraluminal placement of a bronchial blocker and 35 other infants (group B) who underwent CO2 artificial pneumothorax. Clinical characteristics, the degree of lung collapse, and complications were compared.
RESULTS: The degree of lung collapse in group A was significantly higher than that in group B at T2 and T3. The mean arterial pressure (MAP) of group B was significantly lower than that of group A at 10 min and 30 min after OLV. The partial pressure of carbon dioxide (PaCO2) of group B was significantly higher than that of group A at 30 min after OLV. The incidence of hypotension in group B was higher than that in group A.
CONCLUSION: Compared with CO2 artificial pneumothorax, extraluminal placement of a bronchial blocker is associated with a better degree of lung collapse, fewer episodes of hypotension, and lower PaCO2 accumulation during OLV in infants undergoing VATS.