Accuracy of Emergency Medicine Residents Using Point-of-Care Ultrasound (POCUS) to Detect Retained Stingray Barbs.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Richardson S Russ, Pope Jacob, Dickson Lexus, Hart Leslie B, Wilson Casey
Аннотация
BACKGROUND: Stingray envenomation is a common presenting complaint for coastal emergency departments in the United States. Currently, radiograph is the gold standard to evaluate for a retained stingray barb, but ultrasound may be a useful tool to detect retained barbs.
OBJECTIVE: To determine if emergency medicine residents could use ultrasound to identify stingray barbs embedded in animal tissue models. A secondary objective was to determine if resident experience affected their ability to detect stingray barbs.
METHODS: Thirty-two emergency medicine residents participated in the study. After a short didactic session on foreign body identification with ultrasound, they rotated through six simulation stations and were asked to identify whether a stingray barb was present in pig and chicken tissue models. They were given 2 min per model to identify the presence, size, and depth of a stingray barb. Pre- and postexperiment surveys were collected to assess the residents' level of experience and confidence regarding foreign body identification using ultrasound.
RESULTS: Residents accurately identified barbs in chicken drumsticks with a sensitivity of 72.92% (95% confidence interval [CI] 63.89-81.48) and a specificity of 64.58% (95% CI 54.16-74.08), and in pig's feet with a sensitivity of 50.00% (95% CI 39.62-60.38) and specificity of 68.75% (95% CI 58.48-77.82). There was no statistically significant difference regarding accuracy for any outcome measured based on experience or level of training.
CONCLUSIONS: The use of point-of-care ultrasound by novice sonographers lacks sensitivity to identify retained stingray barbs in animal models and is not significantly impacted by resident experience with point-of-care ultrasound.
OBJECTIVE: To determine if emergency medicine residents could use ultrasound to identify stingray barbs embedded in animal tissue models. A secondary objective was to determine if resident experience affected their ability to detect stingray barbs.
METHODS: Thirty-two emergency medicine residents participated in the study. After a short didactic session on foreign body identification with ultrasound, they rotated through six simulation stations and were asked to identify whether a stingray barb was present in pig and chicken tissue models. They were given 2 min per model to identify the presence, size, and depth of a stingray barb. Pre- and postexperiment surveys were collected to assess the residents' level of experience and confidence regarding foreign body identification using ultrasound.
RESULTS: Residents accurately identified barbs in chicken drumsticks with a sensitivity of 72.92% (95% confidence interval [CI] 63.89-81.48) and a specificity of 64.58% (95% CI 54.16-74.08), and in pig's feet with a sensitivity of 50.00% (95% CI 39.62-60.38) and specificity of 68.75% (95% CI 58.48-77.82). There was no statistically significant difference regarding accuracy for any outcome measured based on experience or level of training.
CONCLUSIONS: The use of point-of-care ultrasound by novice sonographers lacks sensitivity to identify retained stingray barbs in animal models and is not significantly impacted by resident experience with point-of-care ultrasound.