MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/jasms.5c00099

Медицинская библиотека · Journal of the American Society for Mass Spectrometry · 2025

Mass Spectral Analysis of Sterols and Other Steroids in Different Ionization Modes: Sensitivity and Oxidation Artifacts.

McCarty Kevin D, Guengerich F Peter

СтатьяПеревод в очереди

Аннотация

In the course of synthetic work and mass spectrometry (MS) with hydroxy steroids, we observed not only the loss of H2O but prominent 2 and 4 amu losses using atmospheric pressure chemical ionization (APCI), leading to confusion of the structural assignments. This loss of 2 amu, which we attributed mainly to oxidation of hydroxyls, varied among 44 steroids and sterols analyzed; 36 showed losses of 2n amu in APCI MS analysis (17/22 Δ5 steroids, 17/19 Δ4 steroids, and 2/3 estrogens). With the Δ5 steroids and sterols, the precursor MH+ was either observed as a minor ion or (more frequently) not detected at all, constituting the base peak in 7/22 cases. With heated electrospray ionization (HESI) MS, 2n amu losses were detected (generally weakly) in 9/44 cases but constituted the base peak in 3/9. In general, the sensitivity (base peak intensity) of steroids correlated with conjugation of the of the steroid frame. Δ4 steroids generally performed best on HESI+ (up to a maximum factor of 8-fold), while Δ5 steroids and sterols performed better on APCI+ (up to >137-fold), except for two trihydroxypregnanes. Estrogens did not show a clear trend. Sensitivity generally increased with the use of NH4F as a mobile phase additive in ESI+ (up to a maximum of 7-fold). We conclude that the prominence of 2n amu losses is variable among steroids and sterols but is more commonly an artifact of APCI MS. These m/z losses can constitute dominant ions that impede detection of the precursor MH+ and complicate structural assignments.

Для цитирования: McCarty Kevin D, Guengerich F Peter. Mass Spectral Analysis of Sterols and Other Steroids in Different Ionization Modes: Sensitivity and Oxidation Artifacts.. Journal of the American Society for Mass Spectrometry. 2025. DOI: 10.1021/jasms.5c00099.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.