MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1586/14779072.2013.867807

Медицинская библиотека · Expert review of cardiovascular therapy · 2013

Pilot evaluation of an integrated monitor-adhesive patch for long-term cardiac arrhythmia detection in India.

Shrivastav Maneesh, Padte Sanjay, Arora Vanita, Biffi Mauro

СтатьяПеревод в очереди

Аннотация

Electrocardiographic monitoring represents one of the most reliable and time-tested methods for reducing ambiguity in cardiac arrhythmia diagnosis. In India, the resting ECG is generally the first tool of choice for in-clinic diagnosis. The external loop recorder (ELR) is another useful tool that compounds the advantages of traditional tools by coupling ambulatory monitoring with a long-term window. Thus, the objective was to test the use of a 7-day ELR for arrhythmia diagnosis in India for a broad range of presenting symptoms. In this study set in the Indian healthcare environment, an auto-triggered, wireless patch-type ELR was used with 125 patients (62.5 ± 16.7 years, 76 males) presenting a broad range of symptoms. Eighty percent of the symptoms were related to syncope, presyncope or palpitations. Patients were administered an ELR for 7-28 days depending on the physician's prescription. Prespecified significant arrhythmias included sinus pause >2 s, symptomatic bradycardia <40 b.p.m., second-degree (and higher) AV block, complete heart block, ventricular fibrillation, sustained/nonsustained ventricular tachycardia (>3 beats), atrial fibrillation (chronic or paroxysmal), atrial flutter and supraventricular tachycardia (SVT) >130 b.p.m. Diagnostic yield was 38% when a stringent tabulation methodology considering only clinically significant arrhythmia was used. When first-degree AV block, premature atrial and ventricular beats, couplets (both atrial and ventricular in origin), bigeminy or trigeminy, or sudden changes in rate (noted as sinus arrhythmia) were included in the calculation, diagnostic yield was 80%. Patient compliance was 98%; patients wore the patch for the entire prescribed monitoring period without disruption. Seventy percent of the reported symptoms corresponded with an arrhythmia. Use of the ELR led to therapy change in 24% of patients: 15 patients went on to receive an implantable cardioverter defibrillator or pacemaker, 4 received ablation therapy and 11 altered their medication after diagnosis. This study demonstrates that a high diagnostic yield for clinically significant arrhythmias and high patient compliance can be achieved with a wearable patch monitor in Indian patients suffering from a variety of symptoms.

Для цитирования: Shrivastav Maneesh, Padte Sanjay, Arora Vanita, Biffi Mauro. Pilot evaluation of an integrated monitor-adhesive patch for long-term cardiac arrhythmia detection in India.. Expert review of cardiovascular therapy. 2013. DOI: 10.1586/14779072.2013.867807.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.