MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2021.09.021

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2021

Percutaneous Arteriovenous Fistula Creation with the WavelinQ 4-French EndoAVF System: A Single-Center Retrospective Analysis of 30 Patients.

Kitrou Panagiotis M, Balta Lamprini, Papachristou Evangelos, Papasotiriou Marios, Katsanos Konstantinos, Theofanis Michail, Papadoulas Spyridon, Anagnostopoulos Fotios, Georgopoulou Georgia Andriana, Goumenos Dimitrios, Karnabatidis Dimitrios

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To retrospectively assess the safety and efficacy of percutaneous arteriovenous fistula (pAVF) creation with the WavelinQ 4-F EndoAVF System.

MATERIALS AND

METHODS

From February 2018 to June 2020, 30 pAVFs were created in 30 consecutive patients (men; age, 55.3 years ± 13.6). Of the 30 patients, 21 (70%) were already on hemodialysis using a central venous catheter. The primary outcome measures were technical success, complications, and cannulation rate. The secondary outcome measures included the number of secondary procedures needed for cannulation, maintenance time to cannulation, and pAVF survival.

RESULTS

Technical success was 100%. The adverse event rate was 6.7% (2/30), including a pseudoaneurysm of the brachial artery that developed immediately after sheath removal and an aneurysm of the anastomosis 17 days after the procedure, which was treated with a covered stent placed in the arterial side. The mean follow-up was 547 days ± 315.7 (range, 14-1,071 days). The cannulation rate was 86.7% (26/30). The mean time to cannulation was 61.3 days ± 32.5 (range, 15-135 days). The mean follow-up after cannulation was 566.2 days ± 252.7 (range, 35-1,041 days). Four pAVFs were thrombosed after cannulation, with 2 of them successfully declotted. Sixteen interventions were needed to achieve cannulation after the index procedure in 15 patients (overall, 0.53 procedures/patient). Seven maintenance endovascular interventions (following cannulation) were performed during the follow-up period in 6 patients (overall, 0.27 procedures/patient, 0.17 procedures/patient-years). For the pAVFs that were cannulated, patency was 96% at 1 year, and 82% at 2 and 3 years, according to the Kaplan-Meier survival analysis.

CONCLUSIONS

This initial experience suggests that pAVF creation is safe and can be successfully performed with high maturation and long-term patency rates. Larger-scale prospective studies are needed to validate the results.

Для цитирования: Kitrou Panagiotis M, Balta Lamprini, Papachristou Evangelos, Papasotiriou Marios, Katsanos Konstantinos, Theofanis Michail, Papadoulas Spyridon, Anagnostopoulos Fotios, Georgopoulou Georgia Andriana, Goumenos Dimitrios, Karnabatidis Dimitrios. Percutaneous Arteriovenous Fistula Creation with the WavelinQ 4-French EndoAVF System: A Single-Center Retrospective Analysis of 30 Patients.. Journal of vascular and interventional radiology : JVIR. 2021. DOI: 10.1016/j.jvir.2021.09.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.