DOI 10.1109/tmi.2023.3309967

Медицинская библиотека · IEEE transactions on medical imaging · 2024

Omnidirectional Monolithic Marker for Intra-Operative MR-Based Positional Sensing in Closed MRI.

Cheung Chim-Lee, Wu Mengjie, Fang Ge, Ho Justin D L, Liang Liyuan, Tan Kel Vin, Lin Fa-Hsuan, Chang Hing-Chiu, Kwok Ka-Wai

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We present a design of an inductively coupled radio frequency (ICRF) marker for magnetic resonance (MR)-based positional tracking, enabling the robust increase of tracking signal at all scanning orientations in quadrature-excited closed MR imaging (MRI). The marker employs three curved resonant circuits fully covering a cylindrical surface that encloses the signal source. Each resonant circuit is a planar spiral inductor with parallel plate capacitors fabricated monolithically on flexible printed circuit board (FPC) and bent to achieve the curved structure. Size of the constructed marker is Ø3-mm ×5 -mm with quality factor > 22, and its tracking performance was validated with 1.5 T MRI scanner. As result, the marker remains as a high positive contrast spot under 360° rotations in 3 axes. The marker can be accurately localized with a maximum error of 0.56 mm under a displacement of 56 mm from the isocenter, along with an inherent standard deviation of 0.1-mm. Accrediting to the high image contrast, the presented marker enables automatic and real-time tracking in 3D without dependency on its orientation with respect to the MRI scanner receive coil. In combination with its small form-factor, the presented marker would facilitate robust and wireless MR-based tracking for intervention and clinical diagnosis. This method targets applications that can involve rotational changes in all axes (X-Y-Z).

Для цитирования: Cheung Chim-Lee, Wu Mengjie, Fang Ge, Ho Justin D L, Liang Liyuan, Tan Kel Vin, Lin Fa-Hsuan, Chang Hing-Chiu, Kwok Ka-Wai. Omnidirectional Monolithic Marker for Intra-Operative MR-Based Positional Sensing in Closed MRI.. IEEE transactions on medical imaging. 2024. DOI: 10.1109/tmi.2023.3309967.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.