MedElevator Войти в исследования
← Поиск публикаций

DOI 10.25270/jic/25.00081

Медицинская библиотека · The Journal of invasive cardiology · 2025

EXPRESS-LAAO protocol with the new WATCHMAN FLX Pro device.

Frazzetto Marco, Dallan Luis Augusto Palma, Texeira Pedro Soares, Taieb Philippe, Tirelli Julia, Feroze Rafey, Alhabdan Nawaf, Cove Alexander, Saeed Yusef, Ukaigwe Anene, Attizzani Guilherme, Filby Steven J

СтатьяПеревод в очереди

Аннотация

This study evaluates the procedural outcomes and short-term follow-up of the WATCHMAN FLX Pro left atrial appendage occlusion (LAAO) device (Boston Scientific) using the EXPRESS-LAAO protocol at a high-volume center. The new device offers enhanced features, including a 40-mm size for large anatomies, additional radiopaque markers for improved positioning, and a hemocompatible coating for faster endothelization. The EXPRESS-LAAO protocol streamlines patient management with pre-procedure computed tomography or cardiac magnetic resonance imaging, intracardiac echocardiography guidance, conscious sedation, and same-day discharge for stable patients. Between June and September 2024, 109 patients (median age 78 years, 48.6% female) underwent LAAO with the WATCHMAN FLX Pro device. Key indications included recurrent falls (33%), gastrointestinal bleeding (29.4%), and very high bleeding risk (21.1%). Procedural success was high (99.1%), with 1 case of cardiac tamponade requiring pericardiocentesis and no in-hospital complications. The 40-mm device was used in 7.3% of cases, proving essential for larger anatomies. At an average follow-up of 49.7 days, there was 1 lacunar stroke without device-related complications and 1 minor bleeding event. The study demonstrates the safety and effectiveness of the WATCHMAN FLX Pro device using the EXPRESS-LAAO protocol. The TruSteer catheter (Boston Scientific) facilitated implantations in complex anatomies, reducing the number of maneuvers. While post-LAAO imaging surveillance was a limitation, this is the first study assessing peri-procedural outcomes with the new device. Findings support its clinical utility in high-risk patients requiring LAAO.

Для цитирования: Frazzetto Marco, Dallan Luis Augusto Palma, Texeira Pedro Soares, Taieb Philippe, Tirelli Julia, Feroze Rafey, Alhabdan Nawaf, Cove Alexander, Saeed Yusef, Ukaigwe Anene, Attizzani Guilherme, Filby Steven J. EXPRESS-LAAO protocol with the new WATCHMAN FLX Pro device.. The Journal of invasive cardiology. 2025. DOI: 10.25270/jic/25.00081.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.