m+Medelevator.RU
← Поиск публикаций
The international journal of cardiovascular imaging · 2022

Normal ranges of left atrial volumes and ejection fraction by 3D echocardiography in adults: a systematic review and meta-analysis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Figliozzi Stefano, Georgiopoulos Georgios, Pateras Kostantinos, Sianis Alexandros, Previtero Marco, Tondi Lara, Petropoulos Ιoannis, Bragato Renato Maria, Papachristidis Alexandros, Condorelli Gianluigi, Takeuchi Masaaki

Аннотация

Increased sizes and dysfunction of the left atrium have been related to adverse outcomes. 3D-echocardiography is more accurate than 2D-echocardiography in estimating LA volumes and ejection fraction. However, the use of 3DE for LA analysis is limited by the absence of established reference values. We performed a systematic review and meta-analysis to provide reference ranges of LA maximum and minimum volumes indexed for body surface area (LAVi max and LAVi min, respectively), and LA-EF assessed by 3DE in healthy adults. Data search was conducted from inception through September 15, 2021, using the following Medical Subject Heading terms: left atrial/atrium, three-dimensional/3D echocardiography. The study protocol was registered in the PROSPERO database (CRD42021252428). 15 studies including 4,226 healthy adults (51% males) and reporting 3DE values of LAVi max, LAVi min and LA-EF were selected. LAVi max, LAVi min and LA-EF mean and reference values were equal to 25.18 ml/m2 (95% CI 23.10, 27.26), 11.10 ml/m2 (10.01, 12.18) and 55.94% (51.92, 59.96), respectively. No influential studies were identified. Pooled estimates per age group- and sex were also estimated. By meta-regression analyses, we identified variability in LA volumes and LA-EF depending on participants' age, ethnicity and number of heart cycles at 3D multi-beat acquisition. At individual patient data analysis conducted on 374 subjects, a software effect on LA-EF was shown. This systematic review and meta-analysis provides reference values of LAVi max, LAVi min and LA-EF assessed by 3DE in healthy adults, encouraging 3DE evaluation of the LA evaluation in daily practice.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты