Correlation of Manifest Refraction and Simulated Keratometry to Tomography Characteristics in Patients With Keratoconus.

Greenstein Steven A, Yu Austin S, Wawrzusin Peter, Ando Airi, Chung Daniel, Garvey Nicholas, Su Becky, Hersh Peter S, Gelles John D

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To report on baseline refractive and keratometric values and their correlation with tomographic characteristics of eyes with keratoconus (KC).

METHODS

Retrospective chart review of patients treated in a single-center cornea and refractive surgery practice. Baseline topographic measurements were reviewed for 1,012 keratoconic eyes of 586 patients between 2008 and 2018. The manifest refraction, thinnest pachymetry (P thin ), corneal astigmatism (K astig ), and the maximum (K max ), steep (K steep ), flat (K flat ), and mean (K mean ) keratometry were analyzed. The location of K max (x, y) was used to determine central (<1 mm), paracentral (1-3 mm), pericentral (3-5 mm), or peripheral (>5 mm) cone locations.

RESULTS

In the entire cohort, the mean manifest sphere was -2.2±4.4 diopters (D) and the cylinder was -3.2±2.3 D. In total, 48.6% of patients had against the rule (ATR) manifest astigmatism (M astig ). The average K astig was 3.8±2.7 D, and unlike the manifest axis, 50.2% of patients had with the rule (WTR) K astig . Patients with a K max less than 50 D had an M astig of -1.9±1.6 D, 45.9% of which was ATR M astig . With respect to baseline tomography measurements, K max , K steep , K flat , and K mean were 58.0±9.4, 50.6±6.5, 46.8±5.9, and 48.6±6.1 D, respectively. There was a weak correlation between K max and simulated keratometry (K steep , K flat , and K mean ) for patients with a K max less than 60 D.

CONCLUSIONS

Simulated keratometry is poorly correlated with KC severity until the disease is more severe. M astig ≥2 D and ATR M astig were correlated with KC at all levels of severity. M astig ≥2 D and ATR M astig may serve as a simple, inexpensive, and widely available indicator for topographic analysis to identify possible KC and suggest further workup; however, further prospective studies are needed to confirm its utility.

Для цитирования: Greenstein Steven A, Yu Austin S, Wawrzusin Peter, Ando Airi, Chung Daniel, Garvey Nicholas, Su Becky, Hersh Peter S, Gelles John D. Correlation of Manifest Refraction and Simulated Keratometry to Tomography Characteristics in Patients With Keratoconus.. Eye & contact lens. 2023. DOI: 10.1097/icl.0000000000001024.