MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.asmr.2020.09.013

Медицинская библиотека · Arthroscopy, sports medicine, and rehabilitation · 2021

Arthroscopic-Assisted Removal of Proximal Humerus Locking Plates With Capsular Release Significantly Improves Range of Motion and Function.

Chan Justin M, Kahlenberg Cynthia, Gadinsky Naomi E, Lorich Dean G, Dines Joshua S

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the clinical outcomes following the arthroscopic removal of proximal humerus locking plates for symptomatic hardware after open reduction and internal fixation (ORIF) of proximal humerus fractures.

METHODS

Patients who underwent arthroscopic removal of hardware (ROH) with capsular release due to pain and/or immobility after receiving locking plates to treat proximal humerus fractures from 2009 to 2016 were identified. Operative and clinic records were reviewed to obtain demographic information, concomitant procedures during ROH, and pre- and postoperative active shoulder range of motion. Postoperative patient-reported outcomes included the QuickDASH, PROMIS Pain Intensity, Constant, and University of California, Los Angeles shoulder rating scale.

RESULTS

In total, 88 patients were included. Patients were evaluated at a minimum of 6 weeks postoperatively after ROH. Patients with pre- and postoperative active range of motion values demonstrated significant improvements in mean forward elevation (n = 69; 78.4%; 115.1° to 152.1°, P < .001), abduction (n = 29; 33.0%; 70.9° to 138.7°, P < .001), external rotation (n = 49; 55.7%; 43.7° to 58.6°, P = .012), and internal rotation (n = 45; 51.1%; 25.7° to 61.9°, P < .001). Patients also reported positive patient-reported scores, including the QuickDASH (4.1 ± 7.8), PROMIS Pain Intensity (3.5 ± 0.9), Constant (84.6 ± 10.7), and University of California, Los Angeles shoulder rating scale (33 ± 2.9), which were measured 70.6 ± 26.6 months postoperatively. There were no surgical complications, no arthroscopic cases were converted to open, but 2 reported refractures (2.3%).

CONCLUSIONS

Arthroscopic-assisted removal of proximal humerus locking plates significantly improves motion and function while allowing for management of concomitant shoulder pathology and potentially avoiding open surgery complications. Given that patients undergoing this procedure frequently have multiple comorbidities, arthroscopic-assisted removal with smaller incisions may minimize risks while restoring shoulder mobility. Therefore, arthroscopic ROH for patients experiencing symptomatic hardware after ORIF is recommended.

LEVEL OF EVIDENCE: Level IV, therapeutic case series.

Для цитирования: Chan Justin M, Kahlenberg Cynthia, Gadinsky Naomi E, Lorich Dean G, Dines Joshua S. Arthroscopic-Assisted Removal of Proximal Humerus Locking Plates With Capsular Release Significantly Improves Range of Motion and Function.. Arthroscopy, sports medicine, and rehabilitation. 2021. DOI: 10.1016/j.asmr.2020.09.013.