MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.avsg.2020.02.022

Медицинская библиотека · Annals of vascular surgery · 2020

Low-profile Zenith Alpha™ Thoracic Stent Graft Modification Using Preloaded Wires for Urgent Repair of Thoracoabdominal and Pararenal Abdominal Aortic Aneurysms.

Han Sukgu M, Tenorio Emanuel R, Mirza Aleem K, Zhang Louis, Weiss Salome, Oderich Gustavo S

СтатьяМногоцентровое исследованиеVideo-Audio MediaПеревод в очереди

Аннотация

BACKGROUND

The aim of this study is to describe a modification technique using the low-profile Cook Zenith Alpha™ thoracic stent graft, and addition of a preloaded wire system, for urgent repair of pararenal (PRA) and thoracoabdominal (TAAA) aortic aneurysms.

METHODS

We analyzed 20 consecutive patients who underwent urgent physician modified endograft repair (PMEG) of PRA and TAAA at 2 institutions. The low-profile Cook Zenith Alpha Thoracic stent graft was modified in accordance with each specific patient anatomic characteristics. End points were technical success, 30-day mortality, and major adverse events (MAEs).

RESULTS

Technical success was achieved in all patients (100%). A total of 76 renal-mesenteric arteries were incorporated by fenestrations (70%) or directional branches (30%) with an average of 3.7 ± 0.6 vessels per patient. There were 6 different types of stent configuration. The most common design consisted of 4 fenestrations (9 patients, 45%). The average of modification time was 110 ± 27 minutes. Total procedure time (including the time for open component) was 242 ± 75 minutes. There was no death within the first 30 days or hospital stay. MAEs occurred in 10 patients (50%). The most common MAEs were acute kidney injury (by Risk, Injury, and Failure; and Loss; and End-stage kidney disease criteria) in 6 patients (30%), estimated blood loss >1 L, respiratory failure requiring reintubation in 2 patients (10%) each, and paraplegia and ischemic colitis in 1 patient (5%) each. One patient (5%) required temporary, new-onset dialysis.

CONCLUSIONS

PMEG using low-profile Zenith Alpha thoracic stent graft was safe with no early mortality and acceptable early morbidity.

Для цитирования: Han Sukgu M, Tenorio Emanuel R, Mirza Aleem K, Zhang Louis, Weiss Salome, Oderich Gustavo S. Low-profile Zenith Alpha™ Thoracic Stent Graft Modification Using Preloaded Wires for Urgent Repair of Thoracoabdominal and Pararenal Abdominal Aortic Aneurysms.. Annals of vascular surgery. 2020. DOI: 10.1016/j.avsg.2020.02.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.