Ventricular tachycardia ablation with pentaspline pulsed field technology in two patients with ischemic cardiomyopathy.
Аннотация
INTRODUCTION
Due to its unique features, pulsed field ablation (PFA) could potentially overcome some limitations of current radiofrequency (RF) ventricular tachycardia (VT) ablation. However, data on the use of PFA in this setting are currently scarce.
METHODS
Two patients with ischemic cardiomyopathy and previously failed RF VT ablations were treated with PFA.
RESULTS
A total of 18 bipolar applications (case1) and seven bipolar applications (case2) were delivered to the infero-lateral and infero-septal areas (case1) and to the apical lateral left ventricular (LV) wall (case2), placing the catheter adjacent to the LV wall in the flower configuration. A rapid cessation of VT and restoration of sinus rhythm were observed during PFA delivery in both cases. Further applications were delivered to achieve complete elimination of late potentials. In case 1, during the in-hospital stay, ECG monitoring did not show VT recurrences. Six-month follow-up was uneventful, with no VT recurrences at ICD interrogation. In case 2, due to postdischarge VT recurrences, a second RF procedure was scheduled 1 month later. The voltage map performed in sinus rhythm showed a low-voltage zone located at the anterolateral wall, near the previous ablation site. Numerous late potentials were recorded. At the 6-month follow-up, no further VT recurrences were documented after RF redo ablation.
CONCLUSION
While the speed of application and potential transmural effect can facilitate the ablation of large diseased endocardial areas, early loss of contact due to difficult pentaspline catheter manipulation in the LV could lead to insufficient contact force and, consequently, inadequate energy penetration.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.