MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.25424

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2016

Comparison of T2, T1rho, and diffusion metrics in assessment of liver fibrosis in rats.

Zhang Hui, Yang Qihua, Yu Taihui, Chen Xiaodong, Huang Jingwen, Tan Cui, Liang Biling, Guo Hua

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the value of T2 , T1 rho, and diffusion metrics in assessment of liver fibrosis in rats.

MATERIALS AND

METHODS

Liver fibrosis in a rat model (n = 72) was induced by injection of carbon tetrachloride (CCl4 ) at 3T. T2 , T1 rho, and diffusion parameters (apparent diffusion coefficient (ADC), Dtrue ) via spin echo (SE) diffusion-weighted imaging (DWI) and stimulated echo acquisition mode (STEAM) DWI with three diffusion times (DT: 80, 106, 186 msec) were obtained in surviving rats with hepatic fibrosis (n = 52) and controls (n = 8). Liver fibrosis stage (F0-F6) was identified based on pathological results using the traditional liver fibrosis staging method for rodents. Nonparametric statistical methods and receiver operating characteristic (ROC) curve analysis were employed to determine the diagnostic accuracy.

RESULTS

Mean T2 , T1 rho, ADC, and Dtrue with DT = 186 msec correlated with the severity of fibrosis with r = 0.73, 0.83, -0.83, and -0.85 (all P < 0.001), respectively. The average areas under the ROC curve at different stages for T1 rho and diffusion parameters (DT = 186 msec) were larger than those of T2 and SE DWI (0.92, 0.92, and 0.92 vs. 0.86, 0.82, and 0.83). The corresponding average sensitivity and specificity for T1 rho and diffusion parameters with a long DT were larger (89.35 and 88.90, 88.36 and 89.97, 90.16 and 87.13) than T2 and SE DWI (90.28 and 79.93, 85.30 and 77.64, 78.21 and 82.41). The performances of T1 rho and Dtrue (DT = 186 msec) were comparable (average AUC: 0.92 and 0.92).

CONCLUSION

Among the evaluated sequences, T1 rho and STEAM DWI with a long DT may serve as superior imaging biomarkers for assessing liver fibrosis and monitoring disease severity.

LEVEL OF EVIDENCE: 1 J. Magn. Reson. Imaging 2017;45:741-750.

Для цитирования: Zhang Hui, Yang Qihua, Yu Taihui, Chen Xiaodong, Huang Jingwen, Tan Cui, Liang Biling, Guo Hua. Comparison of T2, T1rho, and diffusion metrics in assessment of liver fibrosis in rats.. Journal of magnetic resonance imaging : JMRI. 2016. DOI: 10.1002/jmri.25424.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.