BACKGROUND
Severe neonatal hyperbilirubinemia can cause hearing impairment. Bilirubin can be deposited in nerve cells, and the brainstem and the 8th nerve are especially sensitive to bilirubin toxicity. Abnormal changes in brainstem auditory evoked potential (BAEP) can be observed, and the BAEP test measures a nerve potential induced by short, high-frequency sound stimulation; thus, it is able to detect damage to the auditory conduction pathway in children. We aimed to identify relationships between clinical features and BAEP abnormalities in children with hyperbilirubinemia and to assess the predictive power of these risk factors for bilirubin-induced neurological damage.
METHODS
Children with hyperbilirubinemia were evaluated with BAEP and retrospectively enrolled in the study between January 2012 and December 2018. Multivariate logistic regression was performed to identify independent predictors of BAEP abnormalities.
RESULTS
Of the 561 children with hyperbilirubinemia enrolled, the BAEP anomaly group accounted for 198 (35.3%) cases. Except for body weight, there were no significant differences in the general data between the two groups with hyperbilirubinemia (p > 0.05). Univariate analysis showed that prematurity, abnormal umbilical cord, and gestational diabetes during pregnancy were significantly correlated with abnormal BAEP. Multivariate logistic regression analysis identified prematurity (p = 0.001), gestational diabetes (p = 0.03), Premature rupture of membranes (p = 0.013), total serum bilirubin (TSB), bilirubin/albumin (B/A) as independent risk factors for BAEP abnormalities. The prediction accuracy of TSB (Area Under Curve (AUC) = 0.557) and B/A (AUC = 0.566) was low, indicating that abnormal BAEP should be detected by multiple factors.
CONCLUSIONS
Multivariate detection is beneficial for predicting the occurrence of auditory nerve injury in patients with hyperbilirubinemia.