Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures.

Lemoine Marc D, Obergassel Julius, Jaeckle Sandro, Nies Moritz, Taraba Sophia, Mencke Celine, Rieß Jan, My Ilaria, Rottner Laura, Moser Fabian, Ismaili Djemail, Reißmann Bruno, Ouyang Feifan, Kirchhof Paulus, Rillig Andreas, Metzner Andreas

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

AIMS: Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI.

METHODS AND RESULT: A total of 550 consecutively enrolled patients underwent PFA or CBA index PVI. Repeat ablations in patients with symptomatic atrial arrhythmia recurrences were analysed. A total of 22/191 (12%) patients after index PFA-PVI and 44/359 (12%) after CBA-PVI underwent repeat ablation. Reconduction of any pulmonary vein (PV) was detected by multipolar spiral mapping catheter at each PV with careful evaluation of PV potentials and by 3D-mapping in 16/22 patients (73%) after PFA-PVI and in 33/44 (75%) after CBA-PVI (P = 1.000). Of 82 initially isolated PVs after PFA-PVI, 31 (38%) were reconducting; of 169 isolated PVs after CBA-PVI, 63 (37%) were reconducting (P = 0.936). Clinical atrial tachycardia occurred similarly in patients after PFA (5/22; 23%) and CBA (7/44; 16%; P = 0.515). Roof lines were set more often after PFA- (8/22; 36%) compared with CBA-PVI (5/44; 11%; P = 0.023). Repeat procedure duration [PFA: 87 (76, 123) min; CBA: 93 (75, 128) min; P = 0.446] was similar and fluoroscopy time [PFA: 11 (9, 14) min; CBA: 11 (8, 14) min; P = 0.739] equal between groups at repeat ablation.

CONCLUSION

During repeat ablation after previous PFA- or CBA-based PVI, electrical PV-reconduction rates and patterns were similar.

Для цитирования: Lemoine Marc D, Obergassel Julius, Jaeckle Sandro, Nies Moritz, Taraba Sophia, Mencke Celine, Rieß Jan, My Ilaria, Rottner Laura, Moser Fabian, Ismaili Djemail, Reißmann Bruno, Ouyang Feifan, Kirchhof Paulus, Rillig Andreas, Metzner Andreas. Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2024. DOI: 10.1093/europace/euae221.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.