MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0103749

Медицинская библиотека · PloS one · 2014

Diagnosis of Coxiella burnetii infection: comparison of a whole blood interferon-gamma production assay and a Coxiella ELISPOT.

Schoffelen Teske, Limonard Gijs J M, Bleeker-Rovers Chantal P, Bouwman John J M, van der Meer Jos W M, Nabuurs-Franssen Marrigje, Sprong Tom, van Deuren Marcel

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Diagnosis of ongoing or past infection with Coxiella burnetii, the causative agent of Q fever, relies heavily on serology: the measurement of C. burnetii-specific antibodies, reflecting the host's humoral immune response. However, cell-mediated immune responses play an important, probably even more relevant, role in infections caused by the intracellular C. burnetii bacterium. Recent studies have investigated interferon-gamma (IFN-γ) based assays, including a whole-blood IFN-γ production assay and a Coxiella enzyme-linked immunospot (Coxiella ELISPOT), as potential diagnostic tools for Q fever diagnosis. Both are in-house developed assays using stimulating antigens of different origin. The main objective of this study was to compare the test performance of the IFN-γ production assay and the Coxiella ELISPOT for detecting a cellular immune response to C. burnetii in Q fever patients, and to assess the correlation between both assays. To that end, both tests were performed in a well-defined patient group of chronic Q fever patients (n = 16) and a group of healthy seronegative individuals (n = 17). Among patients, both the Coxiella ELISPOT and the IFN-γ production assay detected positive response in 14/16. Among controls, none were positive in the Coxiella ELISPOT, whereas the IFN-γ production assay detected positive results in 1/17 and 3/17, when using Henzerling and Nine Mile as stimulating antigens, respectively. These results suggest the Coxiella ELISPOT has a somewhat higher specificity than the IFN-γ production assay when Nine Mile is used as antigen stimulus. The assays showed moderate correlation: the Spearman correlation coefficient r ranged between 0.37-0.60, depending on the antigens used. Further investigation of the diagnostic potential for C. burnetii infection of both assays is warranted.

Для цитирования: Schoffelen Teske, Limonard Gijs J M, Bleeker-Rovers Chantal P, Bouwman John J M, van der Meer Jos W M, Nabuurs-Franssen Marrigje, Sprong Tom, van Deuren Marcel. Diagnosis of Coxiella burnetii infection: comparison of a whole blood interferon-gamma production assay and a Coxiella ELISPOT.. PloS one. 2014. DOI: 10.1371/journal.pone.0103749.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.