MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2967/jnumed.117.197053

Медицинская библиотека · Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2017

Intragastric Meal Distribution During Gastric Emptying Scintigraphy for Assessment of Fundic Accommodation: Correlation with Symptoms of Gastroparesis.

Orthey Perry, Yu Daohai, Van Natta Mark L, Ramsey Frederick V, Diaz Jesus R, Bennett Paige A, Iagaru Andrei H, Fragomeni Roberto Salas, McCallum Richard W, Sarosiek Irene, Hasler William L, Farrugia Gianrico, Grover Madhusudan, Koch Kenneth L, Nguyen Linda, Snape William J, Abell Thomas L, Pasricha Pankaj J, Tonascia James, Hamilton Frank, Parkman Henry P, Maurer Alan H, NIH Gastroparesis Consortium

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

Impaired fundic accommodation (FA) limits fundic relaxation and the ability to act as a reservoir for food. Assessing intragastric meal distribution (IMD) during gastric emptying scintigraphy (GES) allows for a simple measure of FA. The 3 goals of this study were to evaluate trained readers' (nuclear medicine and radiology physicians) visual assessments of FA from solid-meal GES; develop software to quantify GES IMD; and correlate symptoms of gastroparesis with IMD and gastric emptying.

Methods

After training to achieve a consensus interpretation of GES FA, 4 readers interpreted FA in 148 GES studies from normal volunteers and patients. Mixture distribution and κ-agreement analyses were used to assess reader consistency and agreement of scoring of FA. Semiautomated software was used to quantify IMD (ratio of gastric counts in the proximal stomach to those in the total stomach) at 0, 1, 2, 3, and 4 h after ingestion of a meal. Receiver-operating-characteristic analysis was performed to optimize the diagnosis of abnormal IMD at 0 min (IMD0) with impaired FA. IMD0, GES, water load testing, and symptoms were then compared in 177 patients with symptoms of gastroparesis.

Results

Reader pairwise weighted κ-values for the visual assessment of FA averaged 0.43 (moderate agreement) for normal FA versus impaired FA. Readers achieved 84.0% consensus and 85.8% reproducibility in assessing impaired FA. IMD0 based on the division of the stomach into proximal and distal halves averaged 0.809 (SD, 0.083) for normal FA and 0.447 (SD, 0.132) (P < 0.01) for impaired FA. On the basis of receiver-operating-characteristic analysis, the optimal cutoff for IMD0 discrimination of normal FA from impaired FA was 0.568 (sensitivity, 86.7%; specificity, 91.7%). Of 177 patients with symptoms of gastroparesis, 129 (72.9%) had delayed gastric emptying; 25 (14.1%) had abnormal IMD0 Low IMD0 (impaired FA) was associated with increased early satiety (P = 0.02).

Conclusion

FA can be assessed visually during routine GES with moderate agreement and high reader consistency. Visual and quantitative assessments of FA during GES can yield additional information on gastric motility to help explain patients' symptoms.

Для цитирования: Orthey Perry, Yu Daohai, Van Natta Mark L, Ramsey Frederick V, Diaz Jesus R, Bennett Paige A, Iagaru Andrei H, Fragomeni Roberto Salas, McCallum Richard W, Sarosiek Irene, Hasler William L, Farrugia Gianrico, Grover Madhusudan, Koch Kenneth L, Nguyen Linda, Snape William J, Abell Thomas L, Pasricha Pankaj J, Tonascia James, Hamilton Frank, Parkman Henry P, Maurer Alan H, NIH Gastroparesis Consortium. Intragastric Meal Distribution During Gastric Emptying Scintigraphy for Assessment of Fundic Accommodation: Correlation with Symptoms of Gastroparesis.. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2017. DOI: 10.2967/jnumed.117.197053.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.