MedElevator Войти в исследования
← Поиск публикаций

DOI 10.6061/clinics/2014(04)07

Медицинская библиотека · Clinics (Sao Paulo, Brazil) · 2014

Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses.

Portilla-de Buen Eliseo, Orozco-Mosqueda Abel, Leal-Cortés Caridad, Vázquez-Camacho Gonzalo, Fuentes-Orozco Clotilde, Alvarez-Villaseñor Andrea Socorro, Macías-Amezcua Michel Dassaejv, González-Ojeda Alejandro

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Fibrin glues have not been consistently successful in preventing the dehiscence of high-risk colonic anastomoses. Fibrinogen and thrombin concentrations in glues determine their ability to function as sealants, healers, and/or adhesives. The objective of the current study was to compare the effects of different concentrations of fibrinogen and thrombin on bursting pressure, leaks, dehiscence, and morphology of high-risk ischemic colonic anastomoses using fibrin glue in rats.

METHODS

Colonic anastomoses in adult female Sprague-Dawley rats (weight, 250-350 g) treated with fibrin glue containing different concentrations of fibrinogen and thrombin were evaluated at post-operative day 5. The interventions were low-risk (normal) or high-risk (ischemic) end-to-end colonic anastomoses using polypropylene sutures and topical application of fibrinogen at high (120 mg/mL) or low (40 mg/mL) concentrations and thrombin at high (1000 IU/mL) or low (500 IU/mL) concentrations.

RESULTS

Ischemia alone, anastomosis alone, or both together reduced the bursting pressure. Glues containing a low fibrinogen concentration improved this parameter in all cases. High thrombin in combination with low fibrinogen also improved adherence exclusively in low-risk anastomoses. No differences were detected with respect to macroscopic parameters, histopathology, or hydroxyproline content at 5 days post-anastomosis.

CONCLUSIONS

Fibrin glue with a low fibrinogen content normalizes the bursting pressure of high-risk ischemic left-colon anastomoses in rats at day 5 after surgery.

Для цитирования: Portilla-de Buen Eliseo, Orozco-Mosqueda Abel, Leal-Cortés Caridad, Vázquez-Camacho Gonzalo, Fuentes-Orozco Clotilde, Alvarez-Villaseñor Andrea Socorro, Macías-Amezcua Michel Dassaejv, González-Ojeda Alejandro. Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses.. Clinics (Sao Paulo, Brazil). 2014. DOI: 10.6061/clinics/2014(04)07.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.