Feasibility of low radiation dose retrospectively-gated cardiac CT for functional analysis in adult congenital heart disease.

Groves Daniel W, Olivieri Laura J, Shanbhag Sujata M, Bronson Kathie C, Yu Jeannie H, Nelson Evan A, Rollison Shirley F, Stagliano Michael S, John Anitha S, Kuehl Karen, Chen Marcus Y

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The use of cardiac computed tomography (CT) in the evaluation of adult congenital heart disease patients is limited due to concerns of high radiation doses. The purpose of this study was to prospectively assess whether low radiation dose cardiac CT is feasible to evaluate ventricular systolic function in adults with congenital heart disease.

METHODS

The study group included 30 consecutive patients with significant congenital heart disease who underwent a total of 35 ECG-gated cardiac CT scans utilizing a 320-detector row CT scanner. Each study included a non-contrast scan and subsequent contrast-enhanced retrospectively-gated acquisition. Effective radiation dose was estimated by multiplying the dose length product by a k-factor of 0.014mSv/mGycm.

RESULTS

The mean age of the patients was 34.4±8.9years, 60% were men, and mean body mass index was 24.2±4.3kg/m2. A majority of patients (n=28, 93.3%) had contraindications to cardiac MRI. A tube potential of 80kV was used in 27 (77.1%) of the contrast-enhanced scans. The mean signal-to-noise and contrast-to-noise ratios were 11.5±3.9 and 10.3±3.7, respectively. The median radiation dose for non-contrast and contrast-enhanced images were 0.1mSv (0.07-0.2mSv) and 0.94mSv (0.5-2.1mSv), respectively. All 35 CT scans were successfully analyzed for ventricular systolic function.

CONCLUSIONS

A low radiation contrast-enhanced, retrospectively-gated cardiac CT with a median radiation dose of less than 1mSv was successful in evaluating ventricular systolic function in 30 consecutive adult congenital heart disease patients who underwent a total of 35 scans.

Для цитирования: Groves Daniel W, Olivieri Laura J, Shanbhag Sujata M, Bronson Kathie C, Yu Jeannie H, Nelson Evan A, Rollison Shirley F, Stagliano Michael S, John Anitha S, Kuehl Karen, Chen Marcus Y. Feasibility of low radiation dose retrospectively-gated cardiac CT for functional analysis in adult congenital heart disease.. International journal of cardiology. 2016. DOI: 10.1016/j.ijcard.2016.11.108.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.